Abstract
Managed Aquifer Recharge (MAR), the intentional recharge of aquifers, has surged worldwide in the last 60 years as one of the options to preserve and increase water resources availability. However, estimating the extent of the area impacted by the recharge operations is not an obvious task. In this descriptive study, we monitored the spatiotemporal variation of the groundwater temperature in a phreatic aquifer before and during MAR operations, for 15 days, at the LIFE REWAT pilot infiltration basin using surface water as recharge source. The study was carried out in the winter season, taking advantage of the existing marked difference in temperature between the surface water (cold, between 8 and 13 °C, and in quasi-equilibrium with the air temperature) and the groundwater temperature, ranging between 10 and 18 °C. This difference in heat carried by groundwater was then used as a tracer. Results show that in the experiment the cold infiltrated surface water moved through the aquifer, allowing us to identify the development and extension in two dimensions of the recharge plume resulting from the MAR infiltration basin operations. Forced convection is the dominant heat transport mechanism. Further data, to be gathered at high frequency, and modeling analyses using the heat distribution at different depths are needed to identify the evolution of the recharge bulb in the three-dimensional space.
Subject
Earth-Surface Processes,Waste Management and Disposal,Water Science and Technology,Oceanography
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献