An Array SPRi Biosensor for Simultaneous VEGF-A and FGF-2 Determination in Biological Samples

Author:

Oldak LukaszORCID,Leśniewska Anna,Zelazowska-Rutkowska Beata,Latoch ErykORCID,Lukaszewski Zenon,Krawczuk-Rybak Maryna,Gorodkiewicz Ewa

Abstract

A new method was developed for the simultaneous determination of vascular endothelial growth factor (VEGF-A) and fibroblast growth factor-2 (FGF-2) in blood serum, using biosensors with array Surface Plasmon Resonance imaging (SPRi) detection. It can be applied as a single method for simultaneous VEGF-A and FGF-2 determination or as two separate methods for testing only one selected protein in each case. Validation was carried out for each method. Limit of detection (LOD) and limit of quantification (LOQ) values were determined and were found not to differ significantly from the parameters obtained in comparisons with commercial enzyme-linked immunosorbent assay (ELISA) tests. Tests were carried out to check the robustness of the method. The results indicate a lack of robustness of the analytical method to elevated temperature and pH values other than those recommended by the manufacturers of the reagents (recommended pH = 7.40). The values of recoveries were determined and confirmed the reliability of the results obtained with the use of the newly developed method. The selectivity studies showed no negative influence of other proteins present in the matrix of the tested samples on the results of the VEGF-A and FGF-2 concentration measurements. The developed method is also characterized by high reproducibility of the results obtained and agreement with the VEGF-A and FGF-2 concentration values obtained with commercial ELISA tests. The proposed method offers fast, reproducible, and accurate simultaneous quantification of VEGF-A and FGF-2 in human body fluids. Only 4 µL of test sample are required for simultaneous analysis. The total time for simultaneous analysis of both biomarkers does not exceed 20 min. The developed analytical method is superior to ELISA in terms of analysis time and sample volume for analysis, and it offers lower LOD and LOQ values and allows for the simultaneous analysis of two biomarkers. There is also no need to collect a large number of samples. Standard ELISAs usually have 96 reaction wells. The proposed biosensor can be used to analyse only one sample, without the need to waste reagents on unused reaction sites. In addition, it is possible to regenerate the biosensor and reuse it.

Funder

Dean of the Faculty of Chemistry at the University of Bialystok

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3