Conventional and Digital Impressions for Fabrication of Complete Implant-Supported Bars: A Comparative In Vitro Study

Author:

Vieira Samanta N. V.1ORCID,Lourenço Matheus F.2,Pereira Rodrigo C.3,França Esdras C.1,Vilaça Ênio L.1,Silveira Rodrigo R.1,Silva Guilherme C.1ORCID

Affiliation:

1. Department of Restorative Dentistry, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, MG, Brazil

2. Private Practice, Belo Horizonte 30130-007, MG, Brazil

3. Universo, Belo Horizonte 31140-320, MG, Brazil

Abstract

Obtaining accurate models and well-fitting prostheses during the fabrication of complete implant-supported prostheses has been a significant challenge. Conventional impression methods involve multiple clinical and laboratory steps that can lead to distortions, potentially resulting in inaccurate prostheses. In contrast, digital impressions may eliminate some of these steps, leading to better-fitting prostheses. Therefore, it is important to compare conventional and digital impressions for producing implant-supported prostheses. This study aimed to compare the quality of digital intraoral and conventional impressions by measuring the vertical misfit of implant-supported complete bars obtained using both types of techniques. Five digital impressions using an intraoral scanner and five impressions using elastomer were made in a four-implant master model. The plaster models produced with conventional impressions were scanned in a laboratory scanner to obtain virtual models. Screw-retained bars (n = five) were designed on the models and milled in zirconia. The bars fabricated using digital (DI) and conventional (CI) impressions were screwed to the master model, initially with one screw (DI1 and CI1) and later with four screws (DI4 and CI4), and were analyzed under a SEM to measure the misfit. ANOVA was used to compare the results (p < 0.05). There were no statistically significant differences in the misfit between the bars fabricated using digital and conventional impressions when screwed with one (DI1 = 94.45 µm vs. CI1 = 101.90 µm: F = 0.096; p = 0.761) or four screws (DI4 = 59.43 µm vs. CI4 = 75.62 µm: F = 2.655; p = 0.139). Further, there were no differences when the bars were compared within the same group screwed with one or four screws (DI1 = 94.45 µm vs. DI4 = 59.43 µm: F = 2.926; p = 0.123; CI1 = 101.90 µm vs. CI4 = 75.62 µm: F = 0.013; p = 0.907). It was concluded that both impression techniques produced bars with a satisfactory fit, regardless of whether they were screwed with one or four screws.

Publisher

MDPI AG

Subject

General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3