Effect of primary versus secondary splinting impression techniques on the passive fit of screw-retained implant prosthesis: a randomized clinical trial

Author:

Algabri Radwan SalehORCID,Altayyar Sadeq Ali,Abo-Alrejal Hanan Omar,Alsourori Ali Abdulghani,Alshaibani Dhafer Abdulwasea,Mostafa Marwa Hassan

Abstract

Abstract Background The utilization of splinting techniques for impression copings is commonly advised for complex implant-supported prostheses, as it can enhance the fit of these prostheses. However, there is limited understanding regarding the impact of the secondary splinting of implant analogues, on the passive fit of the prostheses. Limited data are available on the secondary splinting of implant analogues before pouring the impression and its comparison with the primary technique of intraoral splinting of impression copings prior to impression making. Objectives This study's objective was to determine the impact of the primary versus secondary impression splinting techniques using resin on the passive fit of screw-retained prosthesis. Material and methods This randomized clinical trial (RCT) involved two parallel groups consisting of 14 completely edentulous patients, with seven patients in each group. Each patient received a total of eight implants, four implants per arch, resulting in a total of 28 screw-retained prostheses. Two different impression splinting techniques were employed. Group (1) utilized the primary splinting technique, where the impression copings were splinted before taking the impression. In contrast, Group (2) utilized the secondary splinting technique, where the implant analogues were splinted before pouring the impression material. To evaluate the passivity of the screw-retained prostheses in both groups, a single-screw test (one-screw test) was used. Additionally, supplementary methods, including the screw resistance test, were employed. Results The findings of this RCT revealed higher passivity scores for secondary splinting impression pouring technique with a statistically significant difference (P = 0.082). There was a 2.2-fold greater frequency of non-passivity in the primary splinted method. In group (2), the likelihood of non-passivity was four times higher for upper arches prostheses, while there was no significant difference (P = 0.5) observed in both groups for lower arches prostheses. Conclusions The study found that using the secondary splinting impression pouring technique resulted in greater passivity of the implant prostheses compared to the primary splinting impression technique.

Publisher

Springer Science and Business Media LLC

Subject

Management, Monitoring, Policy and Law,Geography, Planning and Development

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3