Improving the Surface Integrity of 316L Steel in the Context of Bioimplant Applications

Author:

Szwajka Krzysztof1ORCID,Zielińska-Szwajka Joanna2ORCID,Trzepieciński Tomasz3ORCID

Affiliation:

1. Faculty of Mechanics and Technology, Department of Integrated Design and Tribology Systems, Rzeszow University of Technology, ul. Kwiatkowskiego 4, 37-450 Stalowa Wola, Poland

2. Faculty of Mechanics and Technology, Department of Component Manufacturing and Production Organization, Rzeszow University of Technology, ul. Kwiatkowskiego 4, 37-450 Stalowa Wola, Poland

3. Department of Manufacturing Processes and Production Engineering, Rzeszow University of Technology, al. Powstańców Warszawy 8, 35-959 Rzeszów, Poland

Abstract

Bioimplants should meet important surface integrity criteria, with the main goal of the manufacturing process to improve wear and corrosion resistance properties. This requires a special approach at the cutting stage. During this research, the impact of the cutting parameters on improving the surface integrity of AISI 316L steel was evaluated. In this context of bioimplant applications, the mean roughness Sa value was obtained in the range of 0.73–4.19 μm. On the basis of the results obtained, a significant effect was observed of both the cutting speed and the feed rate on changes in the microstructure of the near-surface layer. At a cutting speed of 150 m/min, the average grain size was approximately 31 μm. By increasing the cutting speed to 200 m/min, the average grain size increased to approximately 52 μm. The basic austenitic microstructure of AISI 316L steel with typical precipitation of carbides on the grain boundaries was refined at the near-surface layer after the machining process. Changing the cutting speed determined the hardness of the treated and near-surface layers. The maximum value of hardness is reached at a depth of 20 μm and decreases with the depth of measurement. It was also noted that at a depth of up to 240 μm, the maximum hardness of 270–305 HV1 was reached, hence the height of the machining impact zone can be determined, which is approximately 240 μm for almost all machining conditions.

Publisher

MDPI AG

Subject

General Materials Science

Reference46 articles.

1. Implant biomaterials: A comprehensive review;Saini;World J. Clin. Cases,2015

2. Laser surface melting of AISI 316L stainless steel for bio-implant applications;Majumdar;Proc. Natl. Acad. Sci. India Sect. A Phys. Sci.,2018

3. A systematic review of the use of titanium versus stainless steel implants for fracture fixation;Barber;OTA Int.,2021

4. Investigation of a fatigue failure in a stainless steel femoral plate;Marcomini;J. Mech. Behav. Biomed. Mater.,2014

5. Krasicka-Cydzik, E., Mstowski, J., and Ciupik, F.L. (2023, April 13). Materiały Implantowe: Stal a Stopy tytanu. Rozwój Technik Operacyjnego Leczenia Kręgosłupa. Available online: https://lfc.com.pl/wp-content/uploads/2016/08/materialy-implantowe.pdf.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3