Low-Pass Filters for a Temperature Drift Correction Method for Electromagnetic Induction Systems

Author:

Tazifor Tchantcho Martial1ORCID,Zimmermann Egon1ORCID,Huisman Johan Alexander2ORCID,Dick Markus1ORCID,Mester Achim1ORCID,van Waasen Stefan13ORCID

Affiliation:

1. Central Institute of Engineering, Electronics and Analytics (ZEA-2), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany

2. Institute of Bio- and Geosciences Agrosphere (IBG-3), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany

3. Faculty of Engineering, Communication Systems, University of Duisburg-Essen, 47057 Duisburg, Germany

Abstract

Electromagnetic induction (EMI) systems are used for mapping the soil’s electrical conductivity in near-surface applications. EMI measurements are commonly affected by time-varying external environmental factors, with temperature fluctuations being a big contributing factor. This makes it challenging to obtain stable and reliable data from EMI measurements. To mitigate these temperature drift effects, it is customary to perform a temperature drift calibration of the instrument in a temperature-controlled environment. This involves recording the apparent electrical conductivity (ECa) values at specific temperatures to obtain a look-up table that can subsequently be used for static ECa drift correction. However, static drift correction does not account for the delayed thermal variations of the system components, which affects the accuracy of drift correction. Here, a drift correction approach is presented that accounts for delayed thermal variations of EMI system components using two low-pass filters (LPF). Scenarios with uniform and non-uniform temperature distributions in the measurement device are both considered. The approach is developed using a total of 15 measurements with a custom-made EMI device in a wide range of temperature conditions ranging from 10 °C to 50 °C. The EMI device is equipped with eight temperature sensors spread across the device that simultaneously measure the internal ambient temperature during measurements. To parameterize the proposed correction approach, a global optimization algorithm called Shuffled Complex Evolution (SCE-UA) was used for efficient estimation of the calibration parameters. Using the presented drift model to perform corrections for each individual measurement resulted in a root mean square error (RMSE) of <1 mSm−1 for all 15 measurements. This shows that the drift model can properly describe the drift of the measurement device. Performing a drift correction simultaneously for all datasets resulted in a RMSE <1.2 mSm−1, which is considerably lower than the RMSE values of up to 4.5 mSm−1 obtained when using only a single LPF to perform drift corrections. This shows that the presented drift correction method based on two LPFs is more appropriate and effective for mitigating temperature drift effects.

Funder

Deutsche Forschungsgemeinschaft

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference33 articles.

1. Heil, K., and Schmidhalter, U. (2019). Theory and Guidelines for the Application of the Geophysical Sensor EM38. Sensors, 19.

2. Time-lapse geophysical imaging of soil moisture dynamics in tropical deltaic soils: An aid to interpreting hydrological and geochemical processes;Robinson;Water Resour. Res.,2009

3. Knödel, K., Krummel, H., and Lange, G. (2005). Handbuch zur Erkundung des Untergrundes von Deponien und Altlasten, Springer.

4. Assessment of the CMD Mini-Explorer, a New Low-frequency Multi-coil Electromagnetic Device, for Archaeological Investigations;Bonsall;Archaeol. Prospect.,2013

5. Electromagnetic Terrain Conductivity Measurement at Low Induction Numbers;McNeill;Geonics Limited.,1980

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3