Abstract
Current distribution anomaly can be used to indicate the onset of package-related failures modes in Silicon Carbide power MOSFET modules. In this paper, we propose to obtain the wire bond’s magnetic field profile using an array of Tunnel Magneto-Resistance (TMR) sensors, and characterise the small changes in the current density distribution to find the onset of the wire bond degradation processes, including wire bond lift-off, wire bond cracking, and wire bond fracture. We propose a novel condition monitoring technique where a non-galvanic high-bandwidth sensing and a reliability model monitor the health of the power switches. We designed a dedicated calibration set-up to examine the sensor array and calibrated to demonstrate the adequate sensitivity to a minimum 5% current anomaly detection in a single wire bond of the switching devices operating with 50 kHz switching frequency. We use a hardware-in-the-loop (HIL) experimental set-up to replicate wire bond-related failures in a 1200 V/55 A SiC MOSFET power module of a DC/DC Boost converter. Signal conditioning circuits are further designed to amplify and buffer the sensor readings. Experimental results showed the proposed technique is able to detect a wide range of package-related failures.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献