Numerical and Experimental Analysis of Flow and Pulsation in Hump Section of Siphon Outlet Conduit of Axial Flow Pump Device

Author:

Yang Fan,Zhang Yiqi,Yuan Yao,Liu Chao,Li Zhongbin,Nasr Ahmed

Abstract

In order to study the variation law of the flow field and pressure fluctuation in the hump section of the siphon outlet conduit, the flow field characteristics and frequency spectrum characteristics of the flow field were analyzed by combining a physical model test and numerical simulation under the conditions of the interaction between the axial flow pump and siphon outlet conduit, and the influence of the residual circulation at the outlet of the guide vane on the siphon outlet flow was investigated. Based on the influence of the flow field and hydraulic loss in the conduit, the equivalent surface method based on the Q criterion was used to analyze the vortex structure in the siphon outlet conduit and to analyze the internal vortex state. The results showed that with the increase of the flow rate, the intensity of the vortices in the cross-section of the hump section of the siphon outlet conduit decreased gradually, the average velocity circulation decreased gradually and the axial velocity distribution uniformity increased and tended to be stable; water flow stratification existed under three characteristic conditions with no circulation, and the hydraulic loss was greater with the circulation flow while it had a circulation under the small flow condition. Under the low flow rate conditions, the hydraulic loss was 6.6 times higher under the condition of circulation than without. Under a high flow condition, it was 1.3 times. Under the condition of a small flow rate, the vortex structure was distributed centrally at the inlet of the flow conduit, and under the other two characteristic conditions, the vortex structure mostly appeared as a strip; the pressure fluctuation in the hump section had obvious periodicity, and with the increase of the flow rate, the maximum pressure fluctuation amplitude in the hump section decreased gradually; with the decrease of the rotational speed, the pressure amplitude at the same measuring point in the hump section decreased gradually and at the optimum condition. Under the following conditions, the mean value of the pressure amplitude at the top of the hump section was reduced by 69.63%, and the mean value of the pressure amplitude at the bottom of the hump section was reduced by 63.5%. Under all the calculation conditions, the main frequency of pulsation at each measuring point of the hump section was twice the frequency of the rotation.

Funder

the National Natural Science Foundation of China

major projects of the Natural Science Foundation of the Jiangsu Higher Education Institutions of China

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference32 articles.

1. The investigation on high specific speed pump system in eastern route of the South-to-North water diversion project of China;Chao;J. Hydroelectr. Eng.,2005

2. South-to-North Water Transfer project of China;Wang;Yangze River,2005

3. Siphon outlet conduit on full passage cavitation characteristics of axial-flow pumping unit;Daqing;J. Huazhong Univ. Sci. Technol.,2017

4. Impact Analysis of Slope on the Head Loss of Gas-Liquid Two-Phase Flow in Siphon Pipe

5. Ultrasonic Reflection Behavior of R-zone in Carbon Fiber-reinforced Composite Structures and Its Application