Abstract
His bundle pacing (HBP) has several pitfalls, such as the inability to identify the His bundle and lack of capture at acceptable thresholds. The majority of data regarding HBP were obtained using a dedicated non-deflectable delivery system. This study aimed to evaluate the impact of cardiac chamber dimensions on permanent HBP procedural outcomes when using this type of fixed-curve catheter. Seventy-two patients subjected to HBP from the 1st of January to the 31st of December 2021 at our institution were retrospectively reviewed. The baseline clinical characteristics and echocardiographic measurements of all the cardiac chambers were recorded, as well as procedural outcomes (HB electrogram identification and overall procedural success). During the procedure, the HB electrogram was recorded in 59 patients (81.9%) and successful permanent HBP was achieved in 33 patients, representing 45.8% of all the studied patients. Left atrial (LA) and right atrial (RA) volumes were significantly higher in patients without HB electrogram identification. Only LA and RA volumes were statistically associated with HB electrogram localization, while there was no significant association between the echocardiographic parameters and procedural success. LA volumes above 93 mL and RA volumes above 60 mL had an 8.81 times higher chance of failure to localize the HB electrogram compared with patients with lower volumes (p < 0.001). When considering non-deflectable delivery catheters for HBP, careful preprocedural echocardiographic analysis of the atrial volumes could help in the proper selection of implanting tools, thus optimizing the procedural outcomes and costs.