Characterization of Experimentally Observed Complex Interplay between Pulse Duration, Electrical Field Strength, and Cell Orientation on Electroporation Outcome Using a Time-Dependent Nonlinear Numerical Model
-
Published:2023-04-23
Issue:5
Volume:13
Page:727
-
ISSN:2218-273X
-
Container-title:Biomolecules
-
language:en
-
Short-container-title:Biomolecules
Author:
Scuderi Maria1ORCID, Dermol-Černe Janja1ORCID, Batista Napotnik Tina1, Chaigne Sebastien2ORCID, Bernus Olivier2, Benoist David2, Sigg Daniel C.3ORCID, Rems Lea1ORCID, Miklavčič Damijan1ORCID
Affiliation:
1. Faculty of Electrical Engineering, University of Ljubljana, SI-1000 Ljubljana, Slovenia 2. INSERM, CRCTB, U 1045, IHU Liryc, University of Bordeaux, F-33000 Bordeaux, France 3. Medtronic, Cardiac Ablation Solutions, Minneapolis, MN 55105, USA
Abstract
Electroporation is a biophysical phenomenon involving an increase in cell membrane permeability to molecules after a high-pulsed electric field is applied to the tissue. Currently, electroporation is being developed for non-thermal ablation of cardiac tissue to treat arrhythmias. Cardiomyocytes have been shown to be more affected by electroporation when oriented with their long axis parallel to the applied electric field. However, recent studies demonstrate that the preferentially affected orientation depends on the pulse parameters. To gain better insight into the influence of cell orientation on electroporation with different pulse parameters, we developed a time-dependent nonlinear numerical model where we calculated the induced transmembrane voltage and pores creation in the membrane due to electroporation. The numerical results show that the onset of electroporation is observed at lower electric field strengths for cells oriented parallel to the electric field for pulse durations ≥10 µs, and cells oriented perpendicular for pulse durations ~100 ns. For pulses of ~1 µs duration, electroporation is not very sensitive to cell orientation. Interestingly, as the electric field strength increases beyond the onset of electroporation, perpendicular cells become more affected irrespective of pulse duration. The results obtained using the developed time-dependent nonlinear model are corroborated by in vitro experimental measurements. Our study will contribute to the process of further development and optimization of pulsed-field ablation and gene therapy in cardiac treatments.
Funder
Slovenian Research Agency French Agence Nationale de la Recherche Medtronic, Inc.
Subject
Molecular Biology,Biochemistry
Reference69 articles.
1. McBride, S., Avazzadeh, S., Wheatley, A.M., O’Brien, B., Coffey, K., Elahi, A., O’Halloran, M., and Quinlan, L.R. (2021). Ablation Modalities for Therapeutic Intervention in Arrhythmia-Related Cardiovascular Disease: Focus on Electroporation. J. Clin. Med., 10. 2. Pulsed Field Ablation for Pulmonary Vein Isolation in the Treatment of Atrial Fibrillation;Bradley;J. Cardiovasc. Electrophysiol.,2020 3. Verma, A., Haines, D.E., Boersma, L.V., Sood, N., Natale, A., Marchlinski, F.E., Calkins, H., Sanders, P., Packer, D.L., and Kuck, K.-H. (2023). Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial. Circulation. 4. Electroporation of the Heart;Nikolski;EP Eur.,2005 5. Ayuni, E.L., Gazdhar, A., Giraud, M.N., Kadner, A., Gugger, M., Cecchini, M., Caus, T., Carrel, T.P., Schmid, R.A., and Tevaearai, H.T. (2010). In Vivo Electroporation Mediated Gene Delivery to the Beating Heart. PLoS ONE, 5.