Influence of Roof Windows Area Changes on the Classroom Indoor Climate in the Attic Space: A Case Study

Author:

Dolnikova ErikaORCID,Katunsky DusanORCID,Vertal Marian,Zozulak Marek

Abstract

Windows are a complex part of building design and provide a considerable benefit, including to school buildings. For the evaluation of the daylighting conditions prevailing in classrooms, the daylight factor (DF) was considered as the most appropriate parameter for indicating the quantity of admitted daylight. The DF values and CIE overcast sky were calculated using Velux Daylight Visualizer 3 software. The task of the paper is to compare various roof window openings in relation to the level of daylight in the attic, looking to optimize the use of the attic for teaching. The indoor air temperature has a general influence on comfort in the interior, in addition to daylight. In winter, the situation is not critical. The thermal insulation properties of packaging structures are sufficient. The situation is worse in summer, due to the fact that the heat-storage properties are undersized and there is excessive overheating of the indoor air. Four variants of roof windows and their influence on the overall microclimate in the attic are compared. The variant without roof windows is a suitable solution with regard to minimum overheating, but the worst situation for daylight. In order to receive even more light from the window (by moving windows to the top of the roof), we can use variant 2. Based on a combination of daylight calculations and summer temperature, a graphical dependence on window size prediction in terms of top and combined lighting is derived. This was hypothesized without shading the windows. Of course, the shading elements of these windows or cooling are expected in the summer. Finally, the energy required for cooling is compared depending on the size of the windows and achievement of the permissible temperature.

Publisher

MDPI AG

Subject

Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Enerji Verimli Aydınlatma Tasarımı: Farklı Pencere Boyutlarında Optimum Gün Işığı Kullanımı Üzerine Bir Araştırma;Türk Doğa ve Fen Dergisi;2023-12-28

2. Indoor thermal and visual well-being of people with autism: preliminary results from a field study in Denmark;Journal of Physics: Conference Series;2023-11-01

3. Suspended Ceiling Safety for Firefighters in Case of Fire in the Attic;Proceedings of the 6th International Conference on Construction, Architecture and Technosphere Safety;2023

4. Study of Light Transmission and Noise Attenuation Properties of Light Active Glass Materials;Manufacturing Technology;2022-12-11

5. SSP-JCE Volume 17;Selected Scientific Papers - Journal of Civil Engineering;2022-12-01