Author:
Trocquet Claire,Bernhardt Pierre,Guglielmino Maud,Malandain Isabelle,Liaud Céline,Englaro Stéphanette,Le Calvé Stéphane
Abstract
The emergence of new super-insulated buildings to reduce energy consumption places the quality of indoor air at the center of the debate. Among the indoor air pollutants, aldehydes are often present, and formaldehyde is of major interest regarding its multiple sources and its health impact. Therefore, French regulations expect to reduce formaldehyde concentrations below 10 μg m−3 in public buildings by 2023. Formaldehyde and other aldehydes were measured for two weeks during an intensive field campaign conducted in a school recently built and equipped with programmable dual-flow ventilation. Aldehydes were monitored with the ISO 16000-3 reference method based on sampling with 2,4-dinitrophenylhydrazine (DNPH) tubes while formaldehyde concentration was continuously measured by using a sensitive near real-time formaldehyde microanalyzer with a detection limit of 1 µg m−3. Formaldehyde was the major aldehyde. Its concentrations varied in the range of 2–25 µg m−3 and decreased by half when mechanical ventilation was ON, while the other ones were always below 5 µg m−3. In addition, an excellent agreement was observed between the different analytical techniques deployed to quantify formaldehyde levels. The microanalyzer was able to measure fast variations of formaldehyde concentration in the studied room, according to the building's ventilation periods.
Funder
Agence Nationale de la Recherche
Subject
Atmospheric Science,Environmental Science (miscellaneous)
Cited by
10 articles.
订阅此论文施引文献