Abstract
The aim of this in vitro study is to compare the color stability and surface roughness of conventional and self-blending resin composites before and after staining and aging. Three conventional composites (Filtek Z350, IPS Empress Direct, and Estalite Palfique LX5) and one self-blending (Omnichroma) resin composite were used in this study. Sixty discs were prepared and polymerized in a metal mold (n = 15 per group). Samples were then finished and polished by Layan discs. Color testing and roughness testing were measured as a baseline (T0) by a spectrophotometer and profilometry. Samples were then stained with tea for 24 h, water aged for 30 days, and then a second reading (T1) was performed. Finishing and polishing were performed again, and a third reading (T2) was collected. All groups showed significant decrease in all color parameters (L*, a*, and b*); however, after polishing, all groups showed color enhancements matching pre-experiment baseline colors in all color parameters (L*, a*, and b*), except for Estelite Palfique LX5, which showed a significant difference in L relative to the baseline. Furthermore, Estalite Palfique LX5 showed increased roughness after staining compared to the baseline, unlike other groups. No significant differences in color stability were found between self-blending composites and other composite materials. Accelerated aging and staining had minimal effects on the surface roughness of self-blending composite.
Subject
Molecular Medicine,Biomedical Engineering,Biochemistry,Biomaterials,Bioengineering,Biotechnology
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献