Affiliation:
1. Department of Electronic Technology, Faculty of Engineering in Bilbao, University of the Basque Country (UPV/EHU), Plaza Ingeniero Torres Quevedo 1, 48013 Bilbao, Spain
Abstract
One of the most common issues in inverters are open-circuit faults (OPF). In this scenario, a proper fault-tolerant technique must be used to improve the motor performance. Although basic fault-tolerant modulation techniques are normally preferred, this paper proposes a discontinuous pulse-width modulation algorithm (HD-PWM) to operate five-phase inverters under a single OPF. In particular, loss equalization between the remaining switches after a fault occurs is the main objective of the HD-PWM algorithm, thus preventing future faults from occurring. The efficiency and harmonic distortion of the proposed technique are compared to the well-known sinusoidal PWM by simulation and experimentation under OPF conditions. The results obtained show a great performance of the proposed modulation technique, obtaining a relevant efficiency improvement.
Funder
Government of the Basque Country
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering,Control and Optimization,Mechanical Engineering,Computer Science (miscellaneous),Control and Systems Engineering