Abstract
The silicon carbide (SiC) inverter brings great advantages to the motor drive systems of new energy vehicles; however, severe challenges to the bearings also happen. The high dc bus voltage and switching frequency of SiC inverter can increase the discharge frequency and energy when the bearing grease film collapses. As a result, the bearing suffers severe electric corrosion, and the service life of the motor drive system can be shortened. In this paper, the characteristics of common-mode voltage and bearing voltage are analyzed, firstly under space vector pulse width modulation (SVPWM). After that, the common-mode equivalent circuit model of the motor drive system is established. The frequency characteristics of bearing voltage are revealed, and the safe working area is determined. Then, the frequency characteristics of bearing voltage and current are verified based on IGBT and SiC inverters in experiments. After that, by designing a common-mode filter, the bearing voltage and current are significantly attenuated. Furthermore, the active zero state PWM (AZSPWM) is adopted to reduce the common-mode voltage from the inverter. At the same time, combined with the common-mode filter, the bearing voltage and current are further reduced. The experimental results show that the switching frequency has a decisive effect on the amplitude of bearing voltage and current. The bearing voltage can be attenuated to around half of the reference bearing voltage by using the common-mode filter and AZSPWM strategy, respectively. The combination of the common-mode filter and AZSPWM strategy can reduce the bearing voltage to around one-fourth of the reference bearing voltage, which can effectively reduce the breakdown time and discharge energy of the grease oil film.
Funder
Key Research and Development Program of Heilongjiang Province, China Special Funds for Basic Scientific Research and Operation Expenses of Central Universities, China
Reference25 articles.
1. A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors;Zhang;IEEE Trans. Ind. Electron.,2011 2. Cheng, Y., Yang, M., Peng, H., and Du, B. (2023, January 16–19). Research on Suppression Method of Bearing Current for Electric Vehicle Motor Driven by SiC Inverter. Proceedings of the IECON 2023—49th Annual Conference of the IEEE Industrial Electronics Society, Singapore. 3. Im, J.H., Lee, Y.K., Park, J.K., and Hur, J. (2021). Shaft Voltage Reduction Method Using Carrier Wave Phase Shift in IPMSM. Energies, 14. 4. Yang, L., Yang, Y., Wen, J., Jia, L., Yang, E., and Liu, R. (2022). Suppression of Rotor-Grounding Bearing Currents Based on Matching Stator and Rotor Grounding Impedances. Energies, 15. 5. Electrical Bearing Failures in Electric Vehicles;He;Friction,2020
|
|