Abstract
The FY-3E/HIRAS-II (Hyperspectral Infrared Atmospheric Sounder-II), as an infrared hyperspectral instrument onboard the world’s first early morning polar-orbiting satellite, plays a major role in improving the accuracy and timeliness of global numerical weather predictions. In order to assess its observation quality, the geometrically, temporally, and spatially matched scene homogeneous HIRAS-II hyperspectral observations were convolved to the channels corresponding to the Himawari-8/AHI (Advanced Himawari Imager) and FY-3E/MERSI-LL (Medium-Resolution Spectral Imager) imagers from 15 March to 21 April 2022, and their brightness temperature deviation characteristics were statistically calculated in this paper. The results show that the HIRAS-II in-orbit observed brightness temperatures are slightly warmer than the AHI observations in all the matched AHI channels (long wave infrared channel 8 to channel 16) with a mean brightness temperature bias less than 0.65 K. The bias of the atmospheric absorption channel is slightly larger than that of the window channel. A standard deviation less than 0.31 K and a correlation coefficient higher than 0.98 in all channels means that the quality of the observation is satisfactory. The thresholds chosen for the colocation approximation factors (e.g., observation geometry angle, scene uniformity, observation azimuth, and observation time) for matching the HIRAS-II with AHI contribute little and negligible uncertainty to the bias assessment, so the difference between the two observed radiations is considered to be mainly from the systematic bias of the two-instrument measurement. Compared with MERSI-LL window channel 5, the observations of both instruments are very close, with a mean bias of 0.002 K and a standard deviation of 0.31 K. The mean brightness temperature bias (HIRAS-II minus MERSI-LL) of the MERSI-LL water vapor channel 4 is 0.66 K with a standard deviation of 0.22 K. The mean brightness temperature bias of channel 6 and channel 7 is 0.63 K (the standard deviation is 0.36 K) and 0.5 K (the standard deviation is 0.3 K), respectively. The biases of channel 4 are significantly and positively correlated with the target scene temperature, and the biases of channel 6 and 7 show a U-shaped change with the increase in the scene temperature, and the biases are smallest (close to 0 K) when the scene temperature is between 250 K and 280 K. The statistical characteristics of the HIRAS-II–MERSI-LL difference vary minimally and almost constantly over a period of time, indicating that the performance of the HIRAS-II instrument is stable.
Funder
National Natural Science Foundation of China
Subject
General Earth and Planetary Sciences
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献