Airflow Fluctuation from Linear Diffusers in an Office Building: The Thermal Comfort Analysis

Author:

Borowski MarekORCID,Łuczak RafałORCID,Halibart JoannaORCID,Zwolińska KlaudiaORCID,Karch Michał

Abstract

In buildings, the HVAC systems are responsible for a major part of the energy consumption. Incorrect design or selection of the system and improper installation, operation, and maintenance of the systems’ elements may result in increased energy consumption. It is worth remembering that the main aim of the appropriate system is to maintain the high quality of the indoor environment. Appropriate selection of the HVAC solution ensures both thermal and quality parameters of the air, independently of the internal and external heat loads. The microclimate of a room is affected not only by air temperature, humidity, and purity, but also by air velocity in the occupied zone. The proper air velocity distribution prevents discomfort, particularly at workstations. Based on the measurements in the office building, an analysis of velocity profiles of air supplying two different types of linear diffusers was carried out. The analysis was made based on the results of measurements performed with thermoanemometers in the actual facility. During the study, temperature of the supply air was lower that the air in the room. Analysis was focused on the airflow fluctuation and its impact on the users’ comfort. This is an obvious topic but extremely rarely mentioned in publications related to air diffusers. The results show the importance of air fluctuation and its influence on the users’ comfort. During the measurements, the instantaneous air velocity for one of the analyzed types of the diffuser was up to 0.34 m/s, while the average value from the period of 240 s for the same measuring point was relatively low: it was 0.19 m/s. Only including the airflow variability over time allowed for choosing the type of diffuser, which ensures the comfort of users. The measurements carried out for two linear diffusers showed differences in the operation of these diffusers. The velocity in the occupied zone was much higher for one type (0.36 m/s, 3.00 m from diffusers) than for another one (0.22 m/s, 5.00 m from diffusers). The improper selection of the diffuser’s type and its location may increase the risk of the draft in the occupied zone.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

Reference35 articles.

1. Smart ventilation energy and indoor air quality performance in residential buildings: A review

2. Experimental and numerical investigations of a new ventilation supply device based on confluent jets

3. Wentylacja i klimatyzacja. Podstawy;Pełech,2013

4. Air Distribution in Buildings;Khalil,2014

5. Human Thermal Comfort;Parson,2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3