Abstract
This paper deals with a well-known problem of the transient DC-bias current occurring during a phase shift transition in dual active bridge (DAB) DC/DC converters. This phenomenon, if not compensated, can cause damage to the converter or deteriorate its performance. One aim of this paper is to present a solution which allows for the elimination of the undesired transient DC-bias component in current waveforms. This solution is the dual rising edge shift (DRES) compensation algorithm. It provides a very simple implementation and fast settling time within the first half of a switching period. Moreover, the solution is independent on any measurements or system parameter values. It is based on the double-sided single phase shift (DSSPS) modulation, which is described in detail along with a converter model in steady-state. Then, the mechanisms leading to the transient DC-bias are explained, and the compensation algorithm is derived. The performance of the algorithm has been tested using a laboratory prototype. A comprehensive set of tests, involving rapid step changes in power flow and frequency sweep, are provided. Finally, the features of the proposed algorithm are briefly discussed.
Funder
National Center for Research and Development
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献