Abstract
This paper (Part II) is a follow-up paper to our previous work on developing induction motor inter-turn fault (ITF) models (Part I). In this paper, an online ITF diagnosis method of induction motors is proposed by utilizing the negative sequence current as a fault signal based on the fault model of the previous study in part I. The relationships among fault parameters, negative sequence current, and fault copper loss are analyzed with the ITF model. The analyses show that the fault severity index, a function of fault parameters, is directly related to the negative sequence and the copper loss. Therefore, the proposed model-based fault diagnosis method estimates the fault severity index from the negative sequence current and recognizes the ITF. With the estimated fault severity index, the fault copper loss by the ITF, causing thermal degradation, can be calculated. Finally, experiments were performed in various fault conditions to verify the proposed fault diagnosis method.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献