Application of the Hybrid MCDM Method for Energy Modernisation of an Existing Public Building—A Case Study

Author:

Radomski Bartosz1ORCID,Mróz Tomasz2ORCID

Affiliation:

1. Faculty of Environmental Engineering and Mechanical Engineering, Poznań University of Life Science, Wojska Polskiego 28, 60-637 Poznań, Poland

2. Faculty of Environmental Engineering and Energy Poznań, University of Technology, Berdychowo 4, 60-965 Poznań, Poland

Abstract

The existing public utility building belonging to the Forest Experimental Station of the Poznań University of Life Sciences, due to high energy consumption and related costs, has qualified for deep energy modernisation or consideration for the construction of a new building. One of the goals is to achieve carbon neutrality and have a positive energy balance. The article uses the hybrid DEMATEL-AHP/ANP-VIKOR method. The methodology used is distinguished by the creation of a set of decision-making criteria and the identification of the relationship between them, which is determined by conducting a survey of a group of experts using the Delphi method, as well as determining the preferences of the decision-maker using a survey of the target group using social research. Two different models of the decision-maker’s preferences have been developed, taking into account the selected decision criteria, and four acceptable technical solutions have been identified. As a result of the calculations performed, a ranking of the solutions has been developed, from the most preferred to the least accepted. Variant 3B has been identified as the best solution with respect to eight evaluation criteria for both of the adopted models of the decision-maker’s preferences. The ranking index Ri coefficient for this variant ranged between 0.733 and 0.901, while for the other variants, it was lower and amounted to between 0.106 and 0.274 for variant 1, 0.166 and 0.290 for variant 2 and 0.403 and 0.437 for variant 3A. The methodology used for the case study has proved to be applicable. The presented methodology can be used to design new buildings (not only residential) with almost zero energy consumption, as well as those with a positive energy balance, and can also be used for deep energy modernisation. In this article, it was applied for the first time to the energy modernisation of an existing public building.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference54 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3