Design of a Prism-Grating Wide Spectral Range Transmittance Imaging Spectrometer

Author:

Zhang Xu12,Li Bo1,Jiang Xue1,Gu Guochao1,Li Hanshuang1,Wang Xiaoxu1ORCID,Lin Guanyu1

Affiliation:

1. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China

2. University of Chinese Academy of Sciences, Beijing 101408, China

Abstract

As spectroscopic detection technology rapidly advances, back-illuminated InGaAs detectors with a wider spectral range have emerged. Compared to traditional detectors such as HgCdTe, CCD, and CMOS, InGaAs detectors offer a working range of 400–1800 nm and exhibit a quantum efficiency of over 60% in both the visible and near-infrared bands. This is leading to the demand for innovative designs of imaging spectrometers with wider spectral ranges. However, the widening of the spectral range has led to the presence of significant axial chromatic aberration and secondary spectrum in imaging spectrometers. Additionally, there is difficulty in aligning the system optical axis perpendicular to the detector image plane, resulting in increased challenges during post-installation adjustment. Based on chromatic aberration correction theory, this paper presents the design of a wide spectral range transmission prism-grating imaging spectrometer with a working range of 400–1750 nm using Code V. The spectral range of this spectrometer covers both the visible and near-infrared regions, which is beyond the capability of traditional PG spectrometers. In the past, the working spectral range of transmission-type PG imaging spectrometers has been limited to 400–1000 nm. This study’s proposed chromatic aberration correction process involves selecting optical glass materials that match the design requirements and correcting the axial chromatic aberration and secondary spectrum, ensuring that the system axis is perpendicular to the detector plane and easy to adjust during installation. The results show that the spectrometer has a spectral resolution of 5 nm, a root-mean-square spot diagram less than 8 μm over the full field of view, and an optical transfer function MTF greater than 0.6 at a Nyquist frequency of 30 lp/mm. The system size is less than 90 mm. Spherical lenses are employed in the system design to reduce manufacturing costs and complexity while meeting the requirements of wide spectral range, miniaturization, and easy installation.

Funder

National Key Research and Development Plan Project

National Natural Science Foundations of China

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference20 articles.

1. Design of a modular transmission imaging spectrometer;Sun;Spectrosc. Spectr. Anal.,2015

2. Design and research of a self-correcting imaging spectrometer system based on PGP;Xue;J. Opt.,2021

3. Comparison and analysis of wavelength calibration methods for prism—Grating imaging spectrometer;Sun;Results Phys.,2019

4. Imaging spectrometer optical design based on prism- grating-prism dispersing device;Wu;J. Appl. Opt.,2012

5. Extremely achromatic f/1.0 all-spherical camera constructed for the high-resolution echelle spectrometer of the Keck telescope;Epps;Appl. Opt.,1993

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3