Study on the Influencing Factors of the Atomization Rate in a Piezoceramic Vibrating Mesh Atomizer

Author:

Yan Qiufeng,Sun Wanting,Zhang Jianhui

Abstract

On the basis of previous study in our research group, the phenomenon of the dynamic tapered angle was founded, the occurrence of atomization is regarded to derive from the combined effects of the dynamic variation of the micro-tapered aperture, and the difference between forward and reverse flow resistance has been explained by both theories and experiments. It has been revealed that the main influencing factors of the atomization rate are driving voltage, driving frequency, and so on, while the root causes of the various atomization rates still need to be further clarified. In this paper, a micro-tapered aperture worked as a micron-sized tapered flow tube valveless piezoelectric pump in periodic variation. The working principle of such a micro-tapered aperture atomizer was analyzed in detail, and the corresponding formula of the atomization rate was also established. Through measuring the atomization rates at different working frequencies (f), it was established that when the f was set as 122 kHz, the atomization rate reached a maximum value. By building the relationship between the atomization rate and voltage at a fixed resonance frequency, it can be seen that the atomization rate increased with the increase of driving voltage. Subsequently, in order to measure their atomization rates, the micro-tapered apertures of three different outlet diameters were applied, so that the atomization rate was enhanced with the increase of the micro-tapered aperture diameter. Moreover, through examining the atomization rates at different temperatures, it was observed that the atomization rate rose with increasing temperature; while changing the liquid concentration, the atomization rate was also enhanced by the increase in its concentration. Apparently, the impact factors including working frequency, driving voltage, outlet diameter, temperature, and liquid concentration all exert some effects on the atomization rate. It is worth noting that at the first stage, these influence factors indirectly work on the micro-tapered aperture structure or flow state, followed by further effects on the flow resistance. As above-mentioned, in this work, we considered that the root cause influencing the atomization rate in a piezoceramic vibrating mesh atomizer can be attributed to the flow resistance.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3