Optimizing Design Parameters of PLA 3D-Printed Scaffolds for Bone Defect Repair

Author:

Dussault Alexandrine,Pitaru Audrey A.ORCID,Weber Michael H.,Haglund LisbetORCID,Rosenzweig Derek H.ORCID,Villemure Isabelle

Abstract

Current materials used to fill bone defects (ceramics, cement) either lack strength or do not induce bone repair. The use of biodegradable polymers such as PLA may promote patient healing by stimulating the production of new bone in parallel with a controlled degradation of the scaffold. This project aims to determine the design parameters maximising scaffold mechanical performance in such materials. Starting from a base cylindrical model of 10 mm height and of outer and inner diameters of 10 and 4 mm, respectively, 27 scaffolds were designed. Three design parameters were investigated: pore distribution (crosswise, lengthwise, and eccentric), pore shape (triangular, circular, and square), and pore size (surface area of 0.25 mm2, 0.5625 mm2, and 1 mm2). Using the finite element approach, a compressive displacement (0.05 mm/s up to 15% strain) was simulated on the models and the resulting scaffold stiffnesses (N/mm2) were compared. The models presenting good mechanical behaviors were further printed along two orientations: 0° (cylinder sitting on its base) and 90° (cylinder laying on its side). A total of n = 5 specimens were printed with PLA for each of the retained models and experimentally tested using a mechanical testing machine with the same compression parameters. Rigidity and yield strength were evaluated from the experimental curves. Both numerically and experimentally, the highest rigidity was found in the model with circular pore shape, crosswise pore distribution, small pore size (surface area of 0.25 mm2), and a 90° printing orientation. Its average rigidity reached 961 ± 32 MPa from the mechanical testing and 797 MPa from the simulation, with a yield strength of 42 ± 1.5 MPa. The same model with a printing orientation of 0° resulted in an average rigidity of 515 ± 7 MPa with a yield strength of 32 ± 1.6 MPa. Printing orientation and pore size were found to be the most influential design parameters on rigidity. The developed design methodology should accelerate the identification of effective scaffolds for future in vitro and in vivo studies.

Funder

Réseau de recherche en santé buccodentaire et osseuse

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3