Pulsating heat pipe (PHP) is an efficient heat transfer technology applied in the fields of heat dissipation and energy utilization. There are many factors affecting the heat transfer of PHP, including working fluid, filling ratio, inclination angle, etc. The cooling capacity of the cooling water system at the condensing section to the working fluid is also an important factor affecting the starting and operating of PHP. The research on PHP at different cooling water flow rates is of great significance for enhancing the operating performance. An experimental investigation of starting and running performance is carried out on a closed loop PHP with ultrapure water under different inclination angles of 90°, 60° and 30°. The starting and heat transfer performance of PHP with a filling ratio of 50% is obtained by adjusting the heat input in the range of 30–210 W at different cooling water flow rates of 6.7 g/s, 9.7 g/s and 13.9 g/s. The temperature and heat transfer resistance are used for analyzing the heat transfer performance. The results show that the starting mode, initial pulsating temperature and different heat transfer effects are brought about by different cooling water flow rates. It is observed that the cooling water flow rate has no obvious influence on the starting mode of PHP and that the starting mode of PHP is temperature progressive, starting with the increase in cooling water flow rates at a heating input of about 30 W. The influence of cooling water flow rates on the heat transfer performance of PHP is affected in a different way by inclination angles. The heat transfer performance of PHP with an inclination angle of 90° is similar at 6.7 g/s, 9.7 g/s and 13.9 g/s but, under the condition of 60° and 30°, the heat transfer resistance drops within a certain range effectively with an increasing cooling water flow rate from 6.7 g/s to 9.7 g/s and the heat transfer performance does not change significantly with the cooling water flow rate increasing to 13.9 g/s. Thus, there is an optimal value for the cooling water flow rate during the operating of PHP. The inclination angle also has an important effect on the temperature pulsating, and the temperature of PHP affected by gravity is stable with an inclination angle of 90°. However, the reduced influence of gravity on the backflow of the working fluid drops when the inclination angle decreases from 90° to 30°, and the wall temperature increases due to local overheating when the high heat input occurs.
Funder
National Natural Science Foundation of China
R&D Program of Beijing Municipal Education Commission
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献