Abstract
The efficiency issue of energy systems in the oil and gas industry is a crucial factor nowadays. Energy share in the production costs of oil and gas can reach 50%. Among the most important energy equipment are the electric drives of the pumps, compressors, auxiliary units, etc. The paper considered the lifecycle of the electric drives used at oil and gas fields and evaluated their efficiency parameters during periods of operational wear or malfunctioning. At the same time, the lifecycle of the energy equipment was seen as its technical state during operation. Based on the spectral analysis of the current using the finite Fourier transform (FFT), the main frequency components were identified that characterize the type and level of malfunction, taking into account defined efficiency indicators of the electric drive. A technique for assessing the technical state of an electric drive was proposed based on the normalized levels of the amplitudes of the frequency components. Predictive management of the electric drive was implemented in terms of correcting the control system when a malfunction occurs, providing the required efficiency indicators. Boundaries for the technical state of the electric drive were determined. Recommendations for further operation, terms of maintenance and repair or preventive management were presented.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献