A State Machine-Based Droop Control Method Aided with Droop Coefficients Tuning through In-Feasible Range Detection for Improved Transient Performance of Microgrids

Author:

Srikanth MandarapuORCID,Venkata Pavan Kumar YellapragadaORCID

Abstract

 The cascaded droop-voltage-current controller plays a key role in the effective operation of microgrids, where the controller performance is critically impacted by the desigheme, a constant value n of the droop controller. Moreover, in critical loading (e.g.: connection/disconnection of large inductive load), the pre-set value of the droop coefficient brings asymmetry in transient performance leading to instability. Hence, to improve symmetry by reducing the trade-off between transient response and stability margin, this paper proposes a state machine-based droop control method (SMDCM) aided with droop coefficients’ tuning through in-feasible range detection. Here, to realize the issues and the role of the droop controller’s dynamics on the microgrid’s stability, a small-signal stability analysis is conducted, thereby, an in-feasible range of droop values is identified. Accordingly, safe values for droop coefficients are implemented using the state machine concept. This proposed SMDCM is compared with the conventional constant droop control method (CDCM) and fuzzy logic-based droop control method (FLDCM) in terms of frequency/power/voltage characteristics subjected to different power factor (PF) loading conditions. From the results, it is seen that CDCM failed in many metrics under moderate and poor PF loadings. FLDCM is satisfactory under moderate PF loading, but, showed 54 Hz/48 Hz as maximum/minimum frequency values during poor PF loading. These violate the standard limit of ±2%, but SMDCM satisfactorily showed 50.02 Hz and 49.8 Hz, respectively. Besides, FLDCM levied an extra burden of 860 W on the system while it is 550 W with SMDCM. System recovery has taken 0.04 s with SMDCM, which completely failed with FLDCM. Similarly, voltage THD with FLDCM is 58.9% while with SMDCM is 3.08%. Peak voltage due to capacitive load switching is 340V with FLDCM and 150 V with SMDCM. These findings confirm that the proposed SMDCM considerably improved the transient performance of microgrids. 

Funder

VIT-AP University

Publisher

MDPI AG

Subject

Physics and Astronomy (miscellaneous),General Mathematics,Chemistry (miscellaneous),Computer Science (miscellaneous)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3