Abstract
A self-correction method for the drift artifacts of laboratory cone-beam nanoscale X-ray computed tomography (nano-CT) based on the trajectory of projection centroid (TPC) is proposed. This method does not require additional correction phantoms, simplifying the correction process. The whole TPC is estimated by the partial TPC in the optimal projection set. The projection drift is calculated by the measured TPC and the estimated TPC. The interval search method is used so that the proposed method can adapt to the case of a truncated projection due to drift. The fixed-angle scanning experiment of the Siemens star and the partial derivative analysis of the projection position show the necessity of correcting drift artifacts. Further, the Shepp–Logan phantoms with different drift levels are simulated. The results show that the proposed method can effectively estimate the horizontal and vertical drifts within the projection drift range of ±2 mm (27 pixels) with high accuracy. Experiments were conducted on tomato seed and bamboo stick to validate the feasibility of the proposed method for samples with different textures. The correction effect on different reconstructed slices indicates that the proposed method provides performance superior to the reference scanning method (RSM) and global fitting. In addition, the proposed method requires no extra scanning, which improves the acquisition efficiency, as well as radiation utilization.
Funder
National Key Research and Development Project of China
Subject
Radiology, Nuclear Medicine and imaging,Instrumentation,Atomic and Molecular Physics, and Optics
Reference32 articles.
1. Synchrotron X-ray tomographic quantification of microstructural evolution in ice cream – a multi-phase soft solid
2. Positional stability of 2D X-ray images for computer tomography;Vogeler;Proceedings of the International Symposium of Digital Industrial Radiology and Computed Temography,2011
3. Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications
4. Geometric adjustment methods to improve reconstruction quality on rotational cone-beam systems;Reisinger;Proceedings of the 4th Conference on Industrial Computed Tomography (iCT),2012
5. In Investigation of the Focal Spot Drift in Industrial Cone-beam X-ray Computed Tomography;Flay;Proceedings of the Digital Industrial Radiology and Computed Tomography (DIR 2015),2015
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献