An Angle Precision Evaluation Method of Rotary Laser Scanning Measurement Systems with a High-Precision Turntable

Author:

Zhang Rao1,Lin Jiarui1ORCID,Shi Shendong1,Shao Kunpeng1,Zhu Jigui1

Affiliation:

1. State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China

Abstract

Rotary laser scanning measurement systems, such as the workshop measurement positioning system (wMPS), play critical roles in manufacturing industries. The wMPS realizes coordinate measurement through the intersection of multiple rotating fanned lasers. The measurement model of multi-laser plane intersection poses challenges in terms of accurately evaluating the system, making it difficult to establish a standardized evaluation method. The traditional evaluation method is based on horizontal and vertical angles derived from scanning angles, which are the direct observation of wMPS. However, the horizontal- and vertical-angle-based methods ignore the assembly errors of fanned laser devices and mechanical shafts. These errors introduce calculation errors and affect the accuracy of angle measurement evaluation. This work proposes a performance evaluation method for the scanning angle independent of the assembly errors above. The transmitter of the wMPS is installed on a high-precision turntable that provides the angle reference. The coordinates of enhanced reference points (ERP) distributed in the calibration space are measured by the laser tracker multilateration method. Then, the spatial relationship between the transmitter and the turntable is reconstructed based on the high-precision turntable and the good rotational repeatability of the transmitter. The simulation was carried out to validate the proposed method. We also studied the effect of fanned laser devices and shaft assembly errors on horizontal and vertical angles. Subsequently, the calibration results were validated by comparing the residuals with those derived from the space-resection method. Furthermore, the method was also validated by comparing the reference and scanning angles. The results show that the maximum angle measurement error was approximately 2.79″, while the average angle measurement error was approximately 1.26″. The uncertainty (k = 1) of the scanning angle was approximately 1.7″. Finally, the coordinate measurement test was carried out to verify the proposed method by laser tracker. The results show that the average re-scanning error was 2.17″.

Funder

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Atomic and Molecular Physics, and Optics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3