Affiliation:
1. i3N & Department of Physics, University of Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro, Portugal
2. Leibniz Institute of Photonic Technology, Albert-Einstein-Straße 9, 07745 Jena, Germany
Abstract
A hybrid fiber sensor for the simultaneous measurement of pressure and temperature is proposed. The sensor is constituted of a section of silica capillary tube (SCT) whereat access channels are created with two different methods: instilling a bubble on the fiber by employing successive arc discharges on the SCT whilst under pressure and splicing the SCT with another section of SCT with a smaller inner diameter. The reflection-based sensor enhances Fabry–Perot interference (FPI) and antiresonant (AR) guidance, simultaneously, in a single sensing element of a few millimeters. A comparison study between the access channel methods reveals higher spectral visibility for the bubble method and similar pressure and temperature resolutions. For a 2.58 mm long sensor with a bubble, the sensitivity to pressure is 4.09 ± 0.01 nm/MPa and −3.7 ± 0.1 nm/MPa for the FPI and AR, respectively, while its sensitivity to temperature is −0.20 ± 0.02 pm/°C and 24.0 ± 0.5 pm/°C, respectively, for the FPI and AR, which are within the numerically calculated sensitivities. The sensor is robust and has a convenient reflective probe with easy and low-cost fabrication, granting high competitiveness in actual applications.
Subject
Radiology, Nuclear Medicine and imaging,Instrumentation,Atomic and Molecular Physics, and Optics
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献