Research on Best Solution for Improving Indoor Air Quality and Reducing Energy Consumption in a High-Risk Radon Dwelling from Romania

Author:

Mareș Ion-CostinelORCID,Catalina Tiberiu,Istrate Marian-Andrei,Cucoș Alexandra,Dicu Tiberius,Burghele Betty Denissa,Hening Kinga,Popescu Lelia LetitiaORCID,Popescu Razvan Stefan

Abstract

The purpose of this article is the assessment of energy efficiency and indoor air quality for a single-family house located in Cluj-Napoca County, Romania. The studied house is meant to be an energy-efficient building with thermal insulation, low U-value windows, and a high efficiency boiler. Increasing the energy efficiency of the house leads to lower indoor air quality, due to lack of natural ventilation. As the experimental campaign regarding indoor air quality revealed, there is a need to find a balance between energy consumption and the quality of the indoor air. To achieve superior indoor air quality, the proposed mitigation systems (decentralized mechanical ventilation with heat recovery combined with a minimally invasive active sub-slab depressurization) have been installed to reduce the high radon level in the dwelling, achieving an energy reduction loss of up to 86%, compared to the traditional natural ventilation of the house. The sub-slab depressurization system was installed in the room with the highest radon level, while the local ventilation system with heat recovery has been installed in the exterior walls of the house. The results have shown significant improvement in the level of radon decreasing the average concentration from 425 to 70 Bq/m3, respectively the carbon dioxide average of the measurements being around 760 ppm. The thermal comfort improves significantly also, by stabilizing the indoor temperature at 21 °C, without any important fluctuations. The installation of this system has led to higher indoor air quality, with low energy costs and significant energy savings compared to conventional ventilation (by opening windows).

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference49 articles.

1. The European Parliament and The Council of The European Union, Directive (EU) 2018/2002 of the European Parliament and of the Council of 11 December 2018 amending Directive 2012/27/EU on energy efficiency;Off. J. Eur. Union,2018

2. A review of data-driven building energy consumption prediction studies

3. Thermal Performance and Comfort Condition Analysis in a Vernacular Building with a Glazed Balcony

4. Analysis on Energy Consumption of Some Comprehensive Office Building in Jinan

5. Prediction of building's temperature using neural networks models

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Evaluating the Impact of Building Materials on Indoor Air Quality: A Critical Analysis;Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi;2024-08-31

2. Types of Air Pollutants;The Handbook of Environmental Chemistry;2024

3. The Relationship between Radon and Geology: Sources, Transport and Indoor Accumulation;Applied Sciences;2023-06-24

4. Radon—Mitigatory and Control Measures;Environmental Radon;2023

5. Indoor Particle’s Pollution in Bucharest, Romania;Toxics;2022-12-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3