A Rapid UV/Vis Spectrophotometric Method for the Water Quality Monitoring at On-Farm Root Vegetable Pack Houses

Author:

Radzevičius Algirdas,Dapkienė MidonaORCID,Sabienė Nomeda,Dzięcioł JustynaORCID

Abstract

Our research aim was to apply UV/Vis spectrophotometric techniques for the rapid monitoring of the quality of water sourced from on-farm root vegetable washing processes. To achieve this goal, the quality assessment of the washing water and wastewater at different stages of the technological processes was performed using physicochemical, biological, and UV/Vis absorbance measurements as well as statistical methods, such as principal component analysis (PCA) and partial least squares (PLS) regression. Limit values of UV/Vis absorbance at specific wavelengths were predicted in order to adapt them for routine testing and water quality monitoring at the farm packhouses. Results of the lab analyses showed, that the main problems of the water quality were caused by suspended solids (470–3400 mg L−1), organic substances (BOD5 215–2718 mg L−1; COD 540–3229 mg L−1), nitrogen (3–52 mg L−1), phosphorus (1–6 mg L−1), and pathogenic microorganisms (TVC > 300 cfu mL−1, E. coli 5.5 × 103–1.0 × 104 cfu mL−1, intestinal enterococci 2.8 × 102–1.5 × 104 cfu mL−1, coliform bacteria 1.6 × 103–2.0 × 104 cfu mL−1). Suspended solids exceeded the limit values by 10–50 times, organic matter by 10–25 times, dissolved organic carbon by 3–5 times, nitrogen by 3–7 times, total phosphorus by 3–12 times, and microorganisms by 3–10 times. UV/Vis limit values calculated were as follows: A210 nm—3.997–4.009 cm−1, A 240 nm—5.193–5.235 cm−1, A254 nm—4.042–4.047 cm−1, A320 nm—7.387–7.406 cm−1, and A 660 nm—3.937–3.946 cm−1. UV/Vis measurements at A320 nm are proposed for the routine water quality monitoring.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference52 articles.

1. Effect of the Solvent on the Size of Clay Nanoparticles in Solution as Determined Using an Ultraviolet–Visible (UV-Vis) Spectroscopy Methodology

2. BOD5 Estimation by Using UV Absorption and COD for Rapid Industrial Effluent Monitoring

3. Monitoring chromium content in tannery wastewater;Jabari;J. Argent. Chem. Soc.,2009

4. Process Analytical Technology: Spectroscopic Tools and Implementation Strategies for the Chemical and Pharmaceutical Industries;Bakeev,2010

5. Revealing organic carbon–nitrate linear relationship from UV spectra of freshwaters in agricultural environment

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3