Simulation Test on Cooling and Fire Suppression with Liquid Nitrogen in Computer Room of Data Center

Author:

Meng Jianbing1,Wang Tingrong2,Li Guanghua2,Kang Jianhong2

Affiliation:

1. School of Safety Science and Engineering, Anhui University of Science & Technology, Huainan 232001, China

2. Jiangsu Key Laboratory of Fire Safety in Urban Underground Space, China University of Mining and Technology, Xuzhou 221116, China

Abstract

With the rapid development of worldwide computer data center construction, the reliability requirements of the fire-fighting system for data center rooms are also increasing. By using the self-designed simulation platform of liquid nitrogen spray, this paper studies the liquid nitrogen cooling process in the initial heating stage of a computer data center room fire and the liquid nitrogen extinguishing effects for common combustible materials, revealing the feasibility of applying liquid nitrogen to the fire extinguishing system for data center room. The results show that the cooling and inerting effects with quarter sector fan-shaped 6520 spray nozzle are the best among seven types of spray nozzles, the relative temperature changes by more than 50% within 5 min, and the oxygen concentration in the test space drops below 10%. Compared with optical fiber, the ignition range of uninterruptible power supply com-bination during combustion is relatively small. Liquid nitrogen has a significant fire-extinguishing effect on two combustible materials, which can successfully extinguish optical fiber and UPS within 3 min and 2 min, respectively.

Funder

the Qinglan Project of Jiangsu Province

Publisher

MDPI AG

Subject

Earth and Planetary Sciences (miscellaneous),Safety Research,Environmental Science (miscellaneous),Safety, Risk, Reliability and Quality,Building and Construction,Forestry

Reference29 articles.

1. Chen, Y. (2021). Research on Application and Numerical Simulation of Channel Sealing Technology in Data Center Machine Room. [Master’s Thesis, Donghua University].

2. Scaling large data center interconnects: Challenges and solutions;Zhou;Opt. Fiber Technol.,2018

3. An efficient and secure physical security method of data center;Park;J. Secur. Eng.,2015

4. The diagnosis and improving method for the potential hazards of electrical fire;Huang;Fire Technol.,2000

5. Cho, J., Park, B., and Jeong, Y. (2019). Thermal performance evaluation of a data center cooling system under fault conditions. Energies, 12.