A Wearable Head Mounted Display Bio-Signals Pad System for Emotion Recognition

Author:

Wan Chunting,Chen Dongyi,Huang Zhiqi,Luo Xi

Abstract

Multimodal bio-signals acquisition based on wearable devices and using virtual reality (VR) as stimulus source are promising techniques in emotion recognition research field. Numerous studies have shown that emotional states can be better evoked through Immersive Virtual Environments (IVE). The main goal of this paper is to provide researchers with a system for emotion recognition in VR environments. In this paper, we present a wearable forehead bio-signals acquisition pad which is attached to Head-Mounted Displays (HMD), termed HMD Bio Pad. This system can simultaneously record emotion-related two-channel electroencephalography (EEG), one-channel electrodermal activity (EDA), photoplethysmograph (PPG) and skin temperature (SKT) signals. In addition, we develop a human-computer interaction (HCI) interface which researchers can carry out emotion recognition research using VR HMD as stimulus presentation device. To evaluate the performance of the proposed system, we conducted different experiments to validate the multimodal bio-signals quality, respectively. To validate EEG signal, we have assessed the performance in terms of EEG eyes-blink task and eyes-open and eyes-closed task. The EEG eyes-blink task indicates that the proposed system can achieve comparable EEG signal quality in comparison to the dedicated bio-signals measuring device. The eyes-open and eyes-closed task proves that the proposed system can efficiently record alpha rhythm. Then we used signal-to-noise ratio (SNR) and Skin Conductance Reaction (SCR) signal to validate the performance for EDA acquisition system. A filtered EDA signal, with a high mean SNR of 28.52 dB, is plotted on HCI interface. Moreover, the SCR signal related to stimulus response can be correctly extracted from EDA signal. The SKT acquisition system has been validated effectively by the temperature change experiment when subjects are in unpleasant emotion. The pulse rate (PR) estimated from PPG signal achieved the low mean average absolute error (AAE), which is 1.12 beats per minute (BPM) over 8 recordings. In summary, the proposed HMD Bio Pad offers a portable, comfortable and easy-to-wear device for recording bio-signals. The proposed system could contribute to emotion recognition research in VR environments.

Funder

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3