Cold Ablation Robot-Guided Laser Osteotome (CARLO®): From Bench to Bedside

Author:

Ureel MatthiasORCID,Augello Marcello,Holzinger Daniel,Wilken Tobias,Berg Britt-IsabelleORCID,Zeilhofer Hans-Florian,Millesi Gabriele,Juergens Philipp,Mueller Andreas A.ORCID

Abstract

Background: In order to overcome the geometrical and physical limitations of conventional rotating and piezosurgery instruments used to perform bone osteotomies, as well as the difficulties in translating digital planning to the operating room, a stand-alone robot-guided laser system has been developed by Advanced Osteotomy Tools, a Swiss start-up company. We present our experiences of the first-in-man use of the Cold Ablation Robot-guided Laser Osteotome (CARLO®). Methods: The CARLO® device employs a stand-alone 2.94-µm erbium-doped yttrium aluminum garnet (Er:YAG) laser mounted on a robotic arm. A 19-year-old patient provided informed consent to undergo bimaxillary orthognathic surgery. A linear Le Fort I midface osteotomy was digitally planned and transferred to the CARLO® device. The linear part of the Le Fort I osteotomy was performed autonomously by the CARLO® device under direct visual control. All pre-, intra-, and postoperative technical difficulties and safety issues were documented. Accuracy was analyzed by superimposing pre- and postoperative computed tomography images. Results: The CARLO® device performed the linear osteotomy without any technical or safety issues. There was a maximum difference of 0.8 mm between the planned and performed osteotomies, with a root-mean-square error of 1.0 mm. The patient showed normal postoperative healing with no complications. Conclusion: The newly developed stand-alone CARLO® device could be a useful alternative to conventional burs, drills, and piezosurgery instruments for performing osteotomies. However, the technical workflow concerning the positioning and fixation of the target marker and the implementation of active depth control still need to be improved. Further research to assess safety and accuracy is also necessary, especially at osteotomy sites where direct visual control is not possible. Finally, cost-effectiveness analysis comparing the use of the CARLO® device with gold-standard surgery protocols will help to define the role of the CARLO® device in the surgical landscape.

Publisher

MDPI AG

Subject

General Medicine

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3