Abstract
Background: Gait deviations may negatively affect the articular surfaces of the lower extremity joints and lead to some minor degenerative changes. The simplest method for gait evaluation is to assess the symmetry of its parameters, assuming that each undisturbed gait should be symmetrical. This study aims to quantify the degree of asymmetry of kinematic and kinetic parameters caused by the presence of different ankle orthosis settings using Dynamic Time Warping (DTW). Methods: Barefoot gait and gait with four different walker settings were investigated in eighteen healthy persons. Kinematic and kinetic parameters were measured using the Vicon system and Kistler plates. Symmetry was assessed using the DTW method. Results: It was shown that the presence of different ankle orthosis settings significantly disturbs the symmetry of all lower limb kinematic parameters and only knee and hip torques. The highest values of asymmetry were noted for the walker set at 15° of dorsiflexion (15DF). Conclusions: The DTW method allowed us to quantify the degree of asymmetry throughout the gait cycle in relation to barefoot walking. Our results suggest that each orthosis position analysed in this study fulfills its protective function, but gait 15DF can lead to the overload of knee and hip joints.
Subject
Physics and Astronomy (miscellaneous),General Mathematics,Chemistry (miscellaneous),Computer Science (miscellaneous)
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献