Abstract
The stability and accuracy of the on-orbit radiometric calibration of hyperspectral sensors are prerequisites for the quantitative application of satellite hyperspectral data. The Zhuhai-1 micro-nano satellite constellation is composed of eight hyperspectral satellite missions. The Orbita Hyperspectral Sensor (OHS) on board each satellite has a gradient filter spectroscopic design. When observing the Earth, eight integration stages can be set for each band according to different lighting conditions. Due to high manufacturing costs, OHSs are not equipped with on-board calibration devices. Therefore, it is very difficult to accurately calibrate OHSs for all of the integration stages. On the other hand, it is extremely important to ensure radiometric consistency between different OHSs within the Zhuhai-1 micro-nano satellite constellation. To carry out the rapid radiometric calibration of the Zhuhai-1 constellation, an on-orbit radiometric calibration model considering all of the integration stages related to hyperspectral sensors was built based on the BOA reflectance and atmosphere parameters published by the Committee on Earth Observation Satellites (CEOS) radiometric calibration network (RadCalNet). The RadCalNet product was used to derive the TOA radiance base in the Second Simulation of the Satellite Signal in the Solar Spectrum (6S) radiative transfer (RT) model. In this paper, we analyzed the radiometric stability of the same sensor and the consistency of different calibration results regarding four RadCalNet sites, and the on-orbit radiometric performance evaluation of OHSs was also carried out. The data retrieved from OHSs regarding hyperspectral surface reflectance were preliminarily validated using site-synchronous surface reflectance measurements.
Funder
Zhuhai Science and Technology Innovation Bureau
Subject
General Earth and Planetary Sciences
Reference18 articles.
1. Research on Long Time Series Calibration Method of Satellite Remote Sensor Based on Global Calibration Site Network;Wei,2017
2. SkySat Data Quality Assessment within the EDAP Framework
3. Principles and Methods of Radiometric Calibration of Aerospace Optical Remote Sensors;Xingfa,2013
4. In-Orbit Radiometric Calibration of the Planet Dove Constellation
https://digitalcommons.usu.edu/calcon/CALCON2017/All2017Content/23/
5. Railroad Valley Radiometric Calibration Test Site (RadCaTS) as Part of a Global Radiometric Calibration Network (RadCalNet);Czapla-Myers;Proceedings of the IGARSS 2020—2020 IEEE International Geoscience and Remote Sensing Symposium,2020
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献