Retention Force of Removable Partial Dentures with CAD-CAM-Fabricated Telescopic Crowns

Author:

Arnold Christin,Schweyen Ramona,Boeckler Arne,Hey Jeremias

Abstract

The aim of this study was to compare the retention forces after artificial aging of telescopic crowns fabricated either by a conventional lost-wax technique or by computer-aided design/computer-aided manufacturing (CAD-CAM) technology. Two types of telescopic crowns (0°) were fabricated conventionally using high-noble (group A) and non-precious metal (group B). CAD-CAM fabricated telescopic crowns (0°) were made of non-precious metal (group C). Retention forces were assessed before and after artificial aging and after axial and non-axial loading. Initially [I.] and after artificial aging [IV.], specimens of group C (I. 16.2 N; IV. 13.6 N) exhibited the highest retention forces. The retention forces in groups B (I. 12.5 N; IV. 4.6 N) and A (I. 9.6 N; IV. 2.9 N) were found to be lower than those of group C. The retention force differences between the groups were statistically significant (p < 0.001) at all measurement times [I. vs. IV.]. Different fabricated telescopic crowns with approximately identical designs and materials exhibited different retention forces and different long-term retentive behavior. An optimized CAD-CAM process with individually defined design parameters ensured telescopic crowns with a better fit. These findings might influence prospective clinical decision-making.

Publisher

MDPI AG

Subject

General Materials Science

Reference26 articles.

1. Telescopic Crowns on Implants and Teeth: Evaluation of a Clinical Study After 8 to 12 Years

2. Nonprecious Alloy vs Precious Alloy Telescopic Crown–Retained Removable Partial Dentures: Survival and Maintenance Needs

3. Frictional telescopic crowns in severely reduced dentitions: A 5-year clinical outcome study;Szentpétery;Int. J. Prosthodont.,2012

4. Longevity of frictional telescopic crowns in the severely reduced dentition: 3-year results of a longitudinal prospective clinical study;Szentpétery;Quintessence Int.,2010

5. Long-term analysis of telescopic crown retained removable partial dentures: Survival and need for maintenance

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3