Development of a Novel Passive-Dynamic Custom AFO for Drop-Foot Patients: Design Principles, Manufacturing Technique, Mechanical Properties Characterization and Functional Evaluation

Author:

Caravaggi PaoloORCID,Zomparelli Alessandro,Rogati GiuliaORCID,Baleani MassimilianoORCID,Fognani Roberta,Cevolini Franco,Fanciullo Cristina,Cinquepalmi Arianna,Lullini Giada,Berti Lisa,Leardini AlbertoORCID

Abstract

Ankle foot orthoses (AFOs) are medical devices prescribed to support the foot and ankle of drop-foot patients. Passive-dynamic AFOs (PD-AFOs) are an effective solution for less severe cases. While off-the-shelf PD-AFOs are rather inexpensive, they provide poor anatomical fit and do not account for the required patient-specific biomechanical support. Three-dimensional (3D) scanning and manufacturing technologies allow manufacturing PD-AFOs customized for the patient’s anatomy and functional needs. This paper aimed to report the overall procedure for designing and manufacturing a novel, fiberglass-reinforced polyamide, custom PD-AFO. The feasibility of the proposed procedure was tested in a case study. The methodology can be divided into the following steps: (i) foot and leg scanning, (ii) 3D design, and (iii) additive manufacturing via selective laser sintering. A custom PD-AFO was designed and manufactured for a 67-year-old male drop-foot patient following paraparesis in severe discarthrosis after spine stabilization surgery. AFO mechanical properties were measured via an ad hoc setup based on a servohydraulic testing machine. The functional outcome was assessed via gait analysis in three conditions: shod (no AFO), wearing an off-the-shelf PD-AFO, and wearing the patient-specific PD-AFO. As expected, wearing the PD-AFO resulted in increased ankle dorsiflexion in the swing phase with respect to the shod condition. Sagittal rotations of the hip, knee, and ankle joints were similar across PD-AFO conditions, but the custom PD-AFO resulted in faster walking speed with respect to the off-the-shelf (walking speed: 0.91 m/s versus 0.85 m/s). Additionally, the patient scored the custom PD-AFO as more comfortable (VAS score: 9.7 vs. 7.3). While the present analysis should be extended to a larger cohort of drop-foot patients, the novel PD-AFO seems to offer a valid, custom solution for drop-foot patients not satisfied with standard orthotics.

Funder

Ministero della Salute

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3