Comparison of accuracy and speed between plaster casting, high‐cost and low‐cost 3D scanners to capture foot, ankle and lower leg morphology of children requiring ankle‐foot orthoses

Author:

Farhan Muhannad123,Wang Joyce Zhanzi13ORCID,Warncke Rachael4,Cheng Tegan Laura13ORCID,Burns Joshua135ORCID

Affiliation:

1. University of Sydney School of Health Sciences & Children's Hospital at Westmead Sydney New South Wales Australia

2. Faculty of Medical Rehabilitation Science Taibah University Al Madinah Al Munawarah Madinah Saudi Arabia

3. Engineering Prototypes & Implants for Children (EPIC) Lab The Children's Hospital at Westmead Sydney New South Wales Australia

4. Orthotics Department The Children's Hospital at Westmead Sydney New South Wales Australia

5. St. Jude Children's Research Hospital Memphis Tennessee USA

Abstract

AbstractBackgroundTraditional plaster‐cast fabrication of an ankle‐foot orthosis (AFO), although robust, is time‐consuming and cumbersome. 3D scanning is quickly gaining attention as an alternative to plaster casting the foot and ankle region for AFO fabrication. The aim of this study was to assess the accuracy and speed of two high‐performing 3D scanners compared with plaster casting in pediatric patients requiring an AFO.MethodsTen participants (mean age 10.0 ± 3.9 years) prescribed AFOs for a movement disorder were 3D scanned with the high‐cost Artec Eva (Eva) and low‐cost Structure Sensor II (SSII) using one‐person (1p) and two‐person (2p) protocols. Accuracy and speed for both 3D scanners were compared with corresponding plaster cast measures (≤5% acceptable difference). Bland and Altman plots were generated to show mean bias and limits of agreement.ResultsOverall, Eva and SSII were accurate for foot, ankle, and lower leg key clinical landmarks (Eva‐1p: 4.4 ± 7.3%; Eva‐2p: 3.2 ± 7.5%; SSII‐1p: 0.6 ± 7.4%; SSII‐2p: 0.7 ± 8.2%). Bland and Altman plots for the SSII demonstrated lower biases for 1p (bias 0.5 mm, LoA: −12.4–13.5 mm) and 2p (0.4 mm, LoA: −11.4–12.2 mm) protocols compared with Eva for 1p (bias 2.3 mm, LoA: −8.0–12.7 mm) and 2p (1.8 mm, LoA: −10.7–14.3 mm) protocols. The SSII 2p protocol was the fastest 3D scanning method (26.4 ± 11.1 s).ConclusionsThe high‐cost Eva and low‐cost SSII 3D scanners using the 1p and 2p protocols produced comparable accuracy and faster capture of key clinical landmarks compared with plaster cast measures for the fabrication of AFOs in pediatric patients.

Funder

Saudi Arabian Cultural Mission

National Health and Medical Research Council

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3