Comparison of the Axial Fan and Synthetic Jet Cooling Systems

Author:

Smyk EmilORCID,Gil PawełORCID,Gałek Rafał,Przeszłowski ŁukaszORCID

Abstract

Choosing the right cooling device is crucial for the proper operation of electronic equipment. A comparison of the two different cooling devices is presented in this paper: one with a standard axial fan and the other with a synthetic jet actuator. Two distinct sets of operating conditions of the fan and two different loudspeakers for the synthetic jet actuator were used. The experimental setup consisted of a radial heat sink mounted onto a round electric heater and two cooling systems: one with the axial fan and the other with a synthetic jet actuator. From the thermal balance in the specified control volume, the heat sink’s thermal resistance. as well as the coefficient of performance, were determined. The highest difference between the thermal resistance of both cooling systems occurred at a low input power of P = 0.5 W. The heat sink cooled with a synthetic jet had the thermal resistance of R = 0.39 K/W, while the same heat sink cooled with a fan achieved R = 0.23 K/W. Thus, the fan cooling exhibited almost 70% better performance than synthetic jet cooling. For a higher input power of P = 7.0 W, the relative difference in the thermal resistance decreased to the value of 42%. For the input power of P = 7.0 W, the fan-cooled heat sink dissipated the thermal power of Q˙HS=487 W under the temperature difference between the heat sink base and ambient air equal to 60 K. For the same input power and temperature difference, the synthetic jet cooling of the same heat sink dissipated a thermal power of Q˙HS=339 W. Under natural convection, the heat sink dissipated the thermal power of Q˙HS=57 W. Thus, the heat transfer enhancement with fan cooling relative to natural convection was equal to 8.5, while the enhancement with synthetic jet cooling relative to natural convection was equal to 6.0. The modified coefficient of performance and the heat transfer rate of the heat sink per unit temperature difference and unit volume of the cooling device ε are presented. The axial fan performed better in terms of both parameters under consideration. The ε of the investigated device with a fan was around four times higher than in the case of the synthetic jet actuator and eight times higher than in the case of natural convection.

Funder

National Centre for Research and Development

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3