Position Control of a Cost-Effective Bellow Pneumatic Actuator Using an LQR Approach
-
Published:2023-02-09
Issue:2
Volume:12
Page:73
-
ISSN:2076-0825
-
Container-title:Actuators
-
language:en
-
Short-container-title:Actuators
Author:
Gregov Goran1ORCID, Pincin Samuel1, Šoljić Antonio1ORCID, Kamenar Ervin12ORCID
Affiliation:
1. Faculty of Engineering, University of Rijeka, Vukovarska 58, 51000 Rijeka, Croatia 2. Centre for Micro- and Nanosciences and Technologies, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka, Croatia
Abstract
Today, we are witnessing an increasing trend in the number of soft pneumatic actuator solutions in industrial environments, especially due to their human-safe interaction capabilities. An interesting solution in this frame is a vacuum pneumatic muscle actuator (PMA) with a bellow structure, which is characterized by a high contraction ratio and the ability to generate high forces considering its relatively small dimensions. Moreover, such a solution is generally very cost-effective since can be developed by using easily accessible, off-the-shelf components combined with additive manufacturing procedures. The presented research analyzes the precision positioning performances of a newly developed cost-effective bellow PMA in a closed-loop setting, by utilizing a Proportional-Integral-Derivative (PID) controller and a Linear Quadratic Regulator (LQR). In a first instance, the system identification was performed and a numerical model of the PMA was developed. It was experimentally shown that the actuator is characterized by nonlinear dynamical behavior. Based on the numerical model, a PID controller was developed as a benchmark. In the next phase, an LQR that involves a nonlinear pregain term was built. The point-to-point positioning experimental results showed that both controllers allow fast responses without overshoot within the whole working range. On the other hand, it was discovered that the LQR with the corresponding nonlinear pregain term allows an error of a few tens of micrometers to be achieved across the entire working range of the muscle. Additionally, two different experimental pneumatic solutions for indirect and direct vacuum control were analyzed with the aim of investigating the PMA response time and comparing their energy consumption. This research contributes to the future development of the pneumatically driven mechatronics systems used for precise position control.
Subject
Control and Optimization,Control and Systems Engineering
Reference25 articles.
1. Su, H., Hou, X., Zhang, X., Qi, W., Cai, S., Xiong, X., and Guo, J. (2022). Pneumatic soft robots: Challenge and benefits. Actuators, 11. 2. Walker, J., Zidek, T., Harbel, C., Yoon, S., Strickland, F.S., Kumar, S., and Shin, M. (2020). Soft robotics: A review of recent developments of pneumatic soft actuators. Actuators, 9. 3. Soft Robotics: A Perspective—Current Trends and Prospects for the Future;Majidi;Soft Robot.,2014 4. Soft human-machine interfaces: Design, sensing and simulation;Dong;Int. J. Intell. Robot. Appl.,2018 5. A self-sensing soft pneumatic actuator with closed-loop control for haptic feedback wearable devices;Yu;Mater. Des.,2022
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|