Q-Switched 1064/532 nm Laser with Picosecond Pulse to Treat Benign Hyperpigmentations: A Single-Center Retrospective Study

Author:

Silvestri Martina,Bennardo LuigiORCID,Zappia Elena,Tamburi Federica,Cameli Norma,Cannarozzo Giovanni,Nisticò Steven Paul

Abstract

(1) Benign melanoses are a frequent issue in aesthetic dermatology. Solar lentigo, ephelides, café au lait spots, and other melanoses represent a cosmetic issue for a growing number of subjects. The Q-switched 1064/532-nanometer (nm) laser may be considered the gold standard for management of these aesthetic issues. A new generation of Q-switched lasers, capable of concentrating the energy pulse in the spectrum of hundreds of picoseconds, is emerging, promising better results than previous ones. In this paper, we report the use of a Q-switched laser with a picosecond pulse to manage hypermelanoses. (2) Methods: 36 patients seeking melanosis removal were retrospectively enrolled at Magna Graecia University of Catanzaro. Treatment parameters, although variable, were the following: 1064 nm with a pulse duration of 450 picoseconds (ps) for dermic lesions and 532 nm with 370 ps for epidermal lesions. Up to four treatments, with a minimum interval between laser treatments of 30 days, were performed. After the last session, patients’ satisfaction was assessed at a three-month follow up with a Visual Analogue Scale (VAS). Two blinded dermatologists measured the aesthetic outcome using a five-point scale comparing pictures before laser sessions and during follow-up. (3) Results: 36 patients were enrolled; 23 were females (63.9%) and 13 males (36.1%). The mean reported age was 49.2 ± 18.9 years. All participants were assessed with a complete/almost complete melanosis removal at the dermatological evaluation, with a mean VAS score of 9.39 ± 0.90. (4) Conclusions: The Q-switched 1064/532 nm laser may be considered the main weapon in treating benign hypermelanosis. The picosecond pulse seems to guarantee better results than other devices. However, a clinical trial comparing Q-switched nanosecond pulse with picosecond pulse is necessary to confirm this study’s findings.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3