Studies Towards the Development of a Novel, Screen-Printed Carbon-Based, Biosensor for the Measurement of Polyunsaturated Fatty Acids

Author:

Smart AmyORCID,Crew AdrianORCID,Doran Olena,Hart John P.ORCID

Abstract

This paper describes the design, development and characterisation of an electrochemical biosensor for the measurement of linoleic and α-linolenic acid, as representative free polyunsaturated fatty acids (PUFAs), that may be implicated in food safety and food quality. Initial cyclic voltammetric studies were performed with solutions that contained enzyme-generated hydroperoxides of the two PUFAs. These were examined with plain screen-printed carbon electrodes (SPCEs) and screen-printed carbon electrodes containing the electrocatalyst cobalt phthalocyanine (CoPC). The electrocatalytic oxidation peaks obtained with the latter occurred at potentials about 300 mV lower than the those obtained by direct oxidation with the plain SPCEs and were better defined; as these attributes would lead to better selectivity and sensitivity for fatty acid determinations, the CoPC-SPCEs were used in the fabrication of amperometric biosensors. The enzyme lipoxygenase (LOX) was immobilised on the surface of these devices using the crosslinking agent glutaraldehyde. These biosensors were optimised for the measurement of linoleic and α-linolenic acid using amperometry in stirred solution; the optimum conditions were deduced by studying the effect of enzyme loading, pH and temperature on the amperometric responses. These responses were examined over the concentration range 2.0 to 20 µM and the results indicated that the following conditions were optimal: LOX loading 15 units; pH 8.0; temperature 37 °C. Low concentration calibration studies were performed with the two PUFAs and it was shown that the steady state currents were linear between 0.2 and 10 µM for linoleic acid and 0.2 and 10 µM for α-linolenic acid; the detection limits were 24 and 100 nM, respectively. The precision (coefficient of variation, n = 6) was 5.3% for α-linoleic acid and 3.3% for linoleic acid, which were calculated from the steady state current following additions (n = 6) of 0.2 µM PUFA. These results demonstrate that the novel amperometric biosensor holds promise for determining whether foods contain acceptable levels of free fatty acids.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3