A Calibration-Free, 16-Channel, 50-MS/s, 14-Bit, Pipelined-SAR ADC with Reference/Op-Amp Sharing and Optimized Stage Resolution Distribution
-
Published:2022-02-28
Issue:5
Volume:11
Page:749
-
ISSN:2079-9292
-
Container-title:Electronics
-
language:en
-
Short-container-title:Electronics
Author:
Wu Yimin,Ye Fan,Ren Junyan
Abstract
This paper presents a calibration-free, 16-channel, 14-bit, 50-MS/s, pipelined successive approximation register (pipelined-SAR) analog-to-digital converter (ADC) for ultrasound imaging systems. A reference sharing scheme with reduced buffers is proposed to improve area-and-power efficiency, which is essential for multi-channel systems. Based on this, a three-stage, pipelined-SAR ADC architecture with reference/op-amp sharing and optimized stage resolution distribution is proposed. The prototype ADC is designed in a 0.18-μm process with peripheral circuits integrated, including low-voltage differential signaling (LVDS), bandgap, etc. It achieves a robust and calibration-free performance with 68.25-dB signal to noise and distortion ratio (SNDR) and 82.19-dB spurious-free dynamic range (SFDR), translating into a competitive figure of merit (FoM) of 0.47 pJ/conversion-step among other high-resolution ADCs used in ultrasound applications.
Funder
National Key Research and Development Project
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Reference38 articles.
1. Tang, H., Lu, Y., Assaderaghi, F., Daneman, M., Jiang, X., Lim, M., Ng, E., Singhal, U., and Tsai, J.M. (2016, January 31). 3D Ultrasonic Fingerprint Capacitive Fingerprint Sensor. Proceedings of the IEEE International Solid-State Circuits Conference, San Francisco, CA, USA. 2. A Pixel Pitch-Matched Ultrasound Receiver for 3-D Photoacoustic Imaging With Integrated Delta-Sigma Beamformer in 28-nm UTBB FD-SOI;IEEE J. Solid-State Circuits,2017 3. Romero-Morales, C., Martín-Llantino, P., Calvo-Lobo, C., San-Antolín, M., López-López, D., Blanco-Morales, M., and Rodríguez-Sanz, D. (2019). Ultrasound Imaging of the Abdominal Wall and Trunk Muscles in Patients with Achilles Tendinopathy versus Healthy Participants. Diagnostics, 10. 4. Petrusca, L., Varray, F., Souchon, R., Bernard, A., Chapelon, J.Y., Liebgott, H., N’Djin, W.A., and Viallon, M. (2018). Fast Volumetric Ultrasound B-Mode and Doppler Imaging with a New High-Channels Density Platform for Advanced 4D Cardiac Imaging/Therapy. Appl. Sci., 8. 5. Design and Experimental Evaluation of a 256-Channel Dual-Frequency Ultrasound Phased-Array System for Transcranial Blood–Brain Barrier Opening and Brain Drug Delivery;IEEE Trans. Biomed. Eng.,2014
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. A High ENOB 14-Bit ADC without Calibration;Electronics;2024-01-31 2. Analysis and Cancellation of Crosstalk in Multi-Channel Pipelined-SAR ADCs;2022 11th International Conference on Communications, Circuits and Systems (ICCCAS);2022-05-13
|
|