Abstract
In this paper the current sensor fault detector for the permanent-magnet synchronous motor drive system has been presented. The solution is a known method used for induction motor drive systems, tested by authors in simulation for the PMSM drive system. The application is based on the current markers, which enable not only failure detection, but also the location of said failures. Detector operation is based only on the analysis of measurements from current sensors and does not require additional information about other state variables. The aim of the work is to present simulation and experimental studies in field-oriented control (FOC) for the tested current sensor fault detector for various operating conditions of the drive system—variable speed and load.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献