On the Possibility of Universal Chemometric Calibration in X-ray Fluorescence Spectrometry: Case Study with Ore and Steel Samples
-
Published:2023-04-26
Issue:9
Volume:13
Page:5415
-
ISSN:2076-3417
-
Container-title:Applied Sciences
-
language:en
-
Short-container-title:Applied Sciences
Author:
Selivanovs Zahars1, Panchuk Vitaly1, Kirsanov Dmitry1ORCID
Affiliation:
1. Institute of Chemistry, Saint Petersburg State University, Saint Petersburg 198504, Russia
Abstract
The accuracy of X-ray fluorescence spectrometry in quantitative element analysis depends on the particular sample composition (so-called matrix effects). Counteracting these effects requires a large number of calibration samples similar in composition to those under analysis. Application of the model constructed for a particular type of samples is not possible for the analysis of samples having a different matrix composition. A possible solution for this problem can be found in the construction of universal calibration models. We propose the development of these universal models using chemometric tools: influence coefficients—partial least squares regression (IC-PLS) and nonlinear kernel regularized least squares regression. We hypothesize that the application of these methods for constructing calibration models would allow embracing the samples of different types in the framework of a single model. We explored this approach for the case of two substantially different types of samples: ores and steels. The performance of these methods was compared with the fundamental parameters (FP) method, which takes into account matrix effects using theoretical equations and allows handling samples of different elemental composition. IC-PLS significantly outperforms traditional FP in terms of accuracy for predicting the content of Al (root mean squared error of prediction 0.96% vs. 3.87%) and Ti (0.05% vs. 0.09%) and yields comparable results for Si and Mn quantification in ores and steels.
Funder
Russian Science Foundation
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference19 articles.
1. Similarities and differences in geochemical distribution patterns in epiphytic lichens and topsoils from kindergarten grounds in Vilnius;J. Geochem. Explor.,2017 2. Moreno-Santos, A., Rios-Hurtado, J.C., Flores-Villaseñor, S.E., Esmeralda-Gomez, A.G., Guevara-Chavez, J.Y., Lara-Castillo, F.P., and Escalante-Ibarra, G.B. (2023). Hydroxyapatite Growth on Activated Carbon Surface for Methylene Blue Adsorption: Effect of Oxidation Time and CaSiO3 Addition on Hydrothermal Incubation. Appl. Sci., 13. 3. Singh, V.K., Kawai, J., and Tripathi, D.K. (2022). X-Ray Fluorescence in Biological Sciences, John Wiley & Sons, Ltd. 4. Ruschioni, G., Micheletti, F., Bonizzoni, L., Orsilli, J., and Galli, A. (2022). FUXYA2020: A Low-Cost Homemade Portable EDXRF Spectrometer for Cultural Heritage Applications. Appl. Sci., 12. 5. Barago, N., Pavoni, E., Floreani, F., Crosera, M., Adami, G., Lenaz, D., Larese Filon, F., and Covelli, S. (2022). Portable X-ray Fluorescence (pXRF) as a Tool for Environmental Characterisation and Management of Mining Wastes: Benefits and Limits. Appl. Sci., 12.
|
|