CycleGAN-Driven MR-Based Pseudo-CT Synthesis for Knee Imaging Studies

Author:

Vallejo-Cendrero Daniel1ORCID,Molina-Maza Juan Manuel1ORCID,Rodriguez-Gonzalez Blanca1ORCID,Viar-Hernandez David1ORCID,Rodriguez-Vila Borja1ORCID,Soto-Pérez-Olivares Javier2ORCID,Moujir-López Jaime2ORCID,Suevos-Ballesteros Carlos2ORCID,Blázquez-Sánchez Javier2ORCID,Acosta-Batlle José2ORCID,Torrado-Carvajal Angel1ORCID

Affiliation:

1. Medical Image Analysis and Biometry Laboratory, Universidad Rey Juan Carlos, 28933 Móstoles, Spain

2. Department of Radiology, Hospital Universitario Ramón y Cajal, IRYCIS, 28034 Madrid, Spain

Abstract

In the field of knee imaging, the incorporation of MR-based pseudo-CT synthesis holds the potential to mitigate the need for separate CT scans, simplifying workflows, enhancing patient comfort, and reducing radiation exposure. In this work, we present a novel DL framework, grounded in the development of the Cycle-Consistent Generative Adversarial Network (CycleGAN) method, tailored specifically for the synthesis of pseudo-CT images in knee imaging to surmount the limitations of current methods. Upon visually examining the outcomes, it is evident that the synthesized pseudo-CTs show an excellent quality and high robustness. Despite the limited dataset employed, the method is able to capture the particularities of the bone contours in the resulting image. The experimental Mean Absolute Error (MAE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), Zero-Normalized Cross Correlation (ZNCC), Mutual Information (MI), Relative Change (RC), and absolute Relative Change (|RC|) report values of 30.4638 ± 7.4770, 28.1168 ± 1.5245, 0.9230 ± 0.0217, 0.9807 ± 0.0071, 0.8548 ± 0.1019, 0.0055 ± 0.0265, and 0.0302 ± 0.0218 (median ± median absolute deviation), respectively. The voxel-by-voxel correlation plot shows an excellent correlation between pseudo-CT and ground-truth CT Hounsfield units (m = 0.9785; adjusted R2 = 0.9988; ρ = 0.9849; p < 0.001). The Bland–Altman plot shows that the average of the differences is low ((HUCT−HUpseudo−CT = 0.7199 ± 35.2490; 95% confidence interval [−68.3681, 69.8079]). This study represents the first reported effort in the field of MR-based knee pseudo-CT synthesis, shedding light to significantly advance the field of knee imaging.

Funder

Ministerio de Ciencia e Innovación

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3