Biomechanical Effects of Different Auxiliary–Aligner Designs on the Rotation of an Upper Canine: A Finite Element Analysis of a Specific Patient

Author:

D’Antò Vincenzo1ORCID,Bocchino Tecla1,Levatè Carmine1,Buono Raffaele1ORCID,Razionale Armando2ORCID,Barone Sandro2,Savignano Roberto3

Affiliation:

1. Department of Neurosciences, Reproductive Sciences and Oral Sciences, Postgraduate School of Orthodontics, University of Naples “Federico II”, Via Pansini 5, 80131 Naples, Italy

2. Department of Civil and Industrial Engineering, University of Pisa, Largo Lucio Lazzarino 1, 56126 Pisa, Italy

3. Center for Dental Research, School of Dentistry, Loma Linda University, Loma Linda, CA 92350, USA

Abstract

Aim: The objective of this research has been to apply a specific simulation to a patient to assess the biomechanical consequences of rotating an upper canine tooth through different attachment–aligner configurations and to predict the most efficient design using a three-dimensional finite element model of a full maxillary arch of a specific patient. Materials and methods: This was obtained by combining Cone-Beam Computed Tomography (CBCT) with the aim of reconstructing tooth roots and bone tissues, and Surface Structured-Light Scanning for creating digital tooth crown models from the patient’s impressions. This model was imported into the finite element solver (Ansys® 17). Three different attachment–aligner combinations were created through the exploitation of computer-aided design (CAD) procedures, i.e., without attachments, with a couple of attachments and with an attachment and a pressure point. For each simulation, the resulting force–moment (MF) system applied by the aligner to the target tooth, as well as the tooth displacement and rotation, was computed using a workstation based on Intel Xeon CPU E3-1245 v3@3.40 GHz and 16 GB RAM. Simulations reported that by adding the pressure point and the attachment to the standard aligner the amount of Moment z (Mz) delivered to the tooth increased almost two times. Results and conclusions: The maximum tooth displacement (0.85 mm) was obtained with the attachment and pressure point aligner, while the lowest (0.058 mm) was obtained with use of a couple of attachments. Both the attachment and the pressure point have the potential to enhance the appliance’s effectiveness. Particularly, the pressure point showed a higher influence on the load absolute value. The method applied in the present study should be used to retrieve the best design configuration for each patient and specific tooth movement.

Funder

AirNivol S.p.A.

Publisher

MDPI AG