Analysis of Energy Exchange with the Ground in a Two-Chamber Vegetable Cold Store, Assuming Different Lengths of Technological Break, with the Use of a Numerical Calculation Method—A Case Study

Author:

Sokołowski Paweł,Nawalany Grzegorz

Abstract

The paper deals with the impact of the technological break duration during the cold storage cycle on the energy demand of the cold store for vegetables and fruit and the temperature distribution in the ground under the cold store. The studied facility was a two-chamber vegetable cold store located in southern Poland used to store carrots (Daucus carota) for nine months a year. The experiments were conducted for 12 months (01.05.2017–30.04.2018). The technological break during this period lasted three months (from 1 July 2018 to 30 September 2018). Continuous measurements (with 1-h frequency) were made in order to determine the boundary conditions for numerical analysis. The measured parameters included indoor air temperature, outdoor air temperature, ground temperature under the building and in its vicinity. There were 22 measuring points andPT100 sensors were used. The numerical analysis was based on the elementary balances method. WUFIplus® software was used as a calculation supporting tool. The numerical analysis was conducted for 14 calculation variants, with different duration of technological break. The calculation model validation was performed and the results showed a good correlation with the experimental data. The results of experimental studies and of calculations showed a significant impact of the technological break duration on the soil distribution in the ground and the building energy demand. A technological break of less than 4 weeks is the most optimal in the summer. The technological break longer than 4 weeks significantly affects the cooling energy demand in the first days of the cooling cycle and significantly extends the time necessary for the ground and the floor to reach the optimum temperature. The analysis of the floor temperature results (points A1–C1) showed that the technological break longer than four weeks causes the average floor temperature to exceed 4.0 °C. Therefore, the optimum solution is technological break lasting 7–35 days. Absence of technological break results in a decrease of energy gains from the ground by 20% relative to a three-month technological break. The impact of technological break duration was clearly seen in terms of energy losses from the cold store to the ground. In case of a 91-day technological break, the energy losses to the ground were 1289.5 kWh/a, while in case of absence of technological break this value was ninefold lower (147.5 kWh/a).

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3