Cr-Co Oxide Coatings Resistant to Corrosion, Electrodeposited on 304 SS Using an Ethylene Glycol-Water Solvent

Author:

Velázquez-González Carmen E.1,Martínez-Baltodano Francisco J.1ORCID,López-Cuevas Jorge1ORCID,Vargas-Gutiérrez Gregorio1

Affiliation:

1. Cinvestav-Saltillo, Avenida Industria Metalúrgica #1062, Parque Industrial Saltillo-Ramos Arizpe, Ramos Arizpe 25900, Mexico

Abstract

The electrochemical co-deposition of Cr-Co oxide coatings at room temperature on 304 stainless steel (SS) was studied using an electrolyte composed of a mixture of ethylene glycol (EG), hydrated metal chloride salts (MCln∙YH2O), and water as a secondary hydrogen donor (HBD). Metallic Cu and Ni undercoats were applied to improve the adhesion of a posterior Cr-Co metallic and oxide layer. The electroactive events that took place during both electrodeposition processes were studied using cyclic voltammetry (CV) and chronoamperometry. The microstructure and composition of the surface layers were studied using scanning electron microscopy (SEM/EDS), X-ray diffraction (XRD) and cross-sectional elemental mapping via transmission electron microscopy (TEM). The surface of steel with the Cr-Co:EG-H2O coating showed greater resistance to pitting corrosion (123.93 mV) compared to untreated stainless steel (62.3 mV). This sample showed a large hystere-sis area, which is associated with high resistance to pitting corrosion by the occurrence of a re-passivation of the sample at a Erep value of 24.31 mV. After the cyclic potentiodynamic polariza-tion (CPP) test, the lowest specific mass loss (0.001 mg/cm2) was achieved for the AISI 304 SS sample coated using EG-water solvents (Cr-Co:EG-H2O), while the untreated AISI 304 SS reached a higher specific mass loss (0.01 mg/cm2). The Electrochemical Impedance Spectroscopy (EIS) tests showed that the uniform corrosion resistance varied significantly from the untreated AISI 304 SS (35 kΩ) to the coated sample (57 kΩ), which is attributed to the protection provided by the chromium and cobalt oxides coating. The best corrosion resistance achieved was correlated with a superhydrophobic character (with a contact angle of 158.41°) of the Cr-Co coatings. This was in turn a consequence of a needle-like morphology characteristic of these oxides.

Funder

Consejo Nacional de Ciencia y Tecnología

Publisher

MDPI AG

Subject

General Materials Science,Metals and Alloys

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3